Displaying 51 - 75 of 187

Thermodynamic Performance Limits of the Vapor Compression Cycle

January 19, 2014
Author(s)
Piotr A. Domanski, J S. Brown, Jae H. Heo, Mark O. McLinden
This presentation discusses the thermodynamic performance limits of the vapor compression cycle. We have applied evolutionary algorithms to explore the performance of hypothetical refrigerants defined by the thermodynamic parameters used by the extended

Review of alternative cooling technologies

December 18, 2013
Author(s)
S J. Brown, Piotr A. Domanski
This paper considers the alternative cooling technologies studied by Fisher et al. (1994) and assesses their current performance and market potential in reference to vapor compression technology. First, a taxonomy of cooling technologies based on the main

Possibilities, Limits, and Tradeoffs for Refrigerants in the Vapor Compression Cycle

October 29, 2012
Author(s)
Mark O. McLinden, Andrei F. Kazakov, J S. Brown, Piotr A. Domanski, Jae H. Heo
We explore the possibilities for refrigerants having low global warming potential (GWP) using two distinct, but complimentary, approaches. In the first approach, we evaluate the effect of a refrigerant’s fundamental thermodynamic parameters on its

Alternative Cooling Technology Options

August 21, 2011
Author(s)
J S. Brown, Piotr A. Domanski
This paper considers the alternative cooling technologies studied by Fisher et al. (1994) and assesses their current potential to compete with or to replace vapor compression refrigeration technology for space cooling and near-room temperature

IMPACT OF CLASSICAL ASSUMPTIONS IN MODELLING A MICROCHANNEL GAS COOLER

July 5, 2011
Author(s)
Santiago Martinez-Ballester, Jose M. Corberan, Jose Gonzalvez-Macia, Piotr A. Domanski
Most of the current air-to-refrigerant heat exchanger models use the classic ε-NTU approach. These models do not account for 2D longitudinal heat conduction in the tube and the longitudinal heat conduction in the fin. These models, also do not account for

Characterization of Approach Air Distribution for a Finned-Tube Heat Exchanger

February 18, 2011
Author(s)
David A. Yashar, Piotr A. Domanski, Hong H. Cho
The distribution of air flow approaching a finned-tube heat exchanger is one of the predominant factors influencing the heat exchanger’s performance. This paper describes a method for measuring and predicting the inlet air flow distribution using Particle

Residential Heat Pump Heating Performance with Single Faults Imposed

October 29, 2010
Author(s)
William V. Payne, Piotr A. Domanski, Seok Ho Yoon
A heat pump equipped with a thermostatic expansion valve (TXV) was tested in environmental chambers during steady-state no-fault and imposed-fault operation. The studied system was an R410A split residential heat pump with an 8.8 kW nominal cooling

ANALYSIS OF SEGMENT-BY-SEGMENT ? - NTU MODELLING OF A MINICHANNEL CO2 GAS COOLER

July 12, 2010
Author(s)
Santiago M. Ballester, Jose M. Corberan, Jose Gonzalvez-Macia, Piotr A. Domanski
Most of the current air-to-refrigerant heat exchanger models use the classic ε-NTU approach. These models do not account for longitudinal conduction neither in the fin nor in the tube, transverse conduction in the tube, and for the heat conduction between

Residential Heat Pump Heating Performance with Single Faults Imposed

July 11, 2010
Author(s)
Seok H. Yoon, William V. Payne, Piotr A. Domanski
A heat pump equipped with a thermostatic expansion valve (TXV) was tested in environmental chambers during steady-state no-fault and imposed-fault operation. The studied system was an R410A split residential heat pump with an 8.8 kW nominal cooling

Evolutionary Computation Approach to Heat Exchanger Design

June 26, 2010
Author(s)
David A. Yashar, Janusz Wojusiak, Kenneth Kaufman, Piotr A. Domanski
The efficiency of a vapor compression system is strongly influenced by the performance of the finned-tube heat exchangers it employs. Heat exchanger performance is strongly influenced by the refrigerant circuitry, i.e., the connection sequence of the tubes

Evaporator Optimization for Non-Uniform Air Distribution

June 13, 2010
Author(s)
Piotr A. Domanski, David A. Yashar, Sunil Lee
This study demonstrates the performance improvements that can be achieved by accounting for the in-situ air flow distribution during the design phase of a heat exchanger. The heat exchanger used in this study was a two-slab, A-shaped finned-tube evaporator