Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Search Publications

NIST Authors in Bold

Displaying 48151 - 48175 of 143721

Dual frequency comb Fourier transform spectroscopy

October 12, 2010
Author(s)
Ian R. Coddington, William C. Swann, Nathan R. Newbury
Dual coherent frequency combs can be used in Fourier transform spectroscopy (FTS) to generate the full optical response of a sample with high frequency, and time, accuracy and resolution. The approach can be viewed equally well as a multiheterodyne

Further Studies of Bootstrap Variability for ROC Analysis on Large Datasets

October 11, 2010
Author(s)
Jin Chu Wu, Alvin F. Martin, Raghu N. Kacker
The nonparametric two-sample bootstrap is successfully applied to computing the measurement uncertainties in receiver operating characteristic (ROC) analysis on large datasets in areas such as biometrics, speaker recognition system, etc. To determine the

Localized Diffusive Motion on Two Different Time Scales in Solid Alkane Nanoparticles

October 11, 2010
Author(s)
Siao-Kwan Wang, E. Mamontov, Mengjun Bai, F.Y. Hansen, Haskell Taub, John R. Copley, Victoria Garcia Sakai, Goran Gasparovic, Timothy Jenkins, Madhu Sudan Tyagi, Kenneth W. Herwig, David B. Neumann, Wouter Montfrooij, U.G. Volkmann
High-energy-resolution quasielastic neutron scattering on three complementary spectrometers has been used to investigate molecular diffusive motion in solid nanoparticles of the alkane n-C 32H^66^. Nontranslational molecular diffusive motion in the plastic

Matching Observed Alpha Helix Lengths to Predicted Secondary Structure

October 11, 2010
Author(s)
Brian D. Cloteaux
Because of the complexity in determining the 3D structure of a protein, the use of partial information determined from experimental techniques can greatly reduce the overall computational expense. We investigate the problem of matching experimentally

Validation of Two-Sample Bootstrap in ROC Analysis on Large Datasets Using AURC

October 11, 2010
Author(s)
Jin Chu Wu, Alvin F. Martin, Raghu N. Kacker
Sampling variability can result in uncertainties of measures. The nonparametric two-sample bootstrap method has been used to compute uncertainties of measures in receiver operating characteristic (ROC) analysis on large datasets, such as the standard error

Active Millimeter-Wave Imaging: Detection of Concealed Weapons

October 10, 2010
Author(s)
Randy Direen, David R. Novotny, Katherine MacReynolds
Images are constructed from data collected with a near- eld planar scannar and a network analyzer. Data are collected at millimeter-wave frequencies. This imaging system is used to image both metal and nonmetal objects.

An Inconvenient Truth About Tunneled Authentications

October 10, 2010
Author(s)
Katrin Hoeper, Lidong Chen
In recent years, it has been a common practice to execute client authentications for network access inside a protective tunnel. Man-in-the-middle (MitM) attacks on such tunneled authentications have been discovered early on and cryptographic bindings are

Link Relationship Measurements in Load-Modulated UHF RFID

October 10, 2010
Author(s)
Daniel G. Kuester, David R. Novotny, Jeffrey R. Guerrieri
This paper investigates the relative roles of the forward and reverse links in determining the operational range of passive UHF RFID systems. The relative importance the links are discussed first in the free field as a first-order model. We then present

Microencapsulated POSS in Cellulose Using 1-Ethyl-3-Methylimidazolium Acetate

October 10, 2010
Author(s)
Douglas M. Fox, Mauro Zammarano, Jeffrey W. Gilman
Polyhedral oligomeric silsesquioxane (POSS) and cellulose were reacted in the ionic liquid, 1-ethyl-3-methylimidazolium acetate (EmiAc). Side reactions between the EmiAc and each reactant were prevalent, but use of water as the coagulating solvent produced
Displaying 48151 - 48175 of 143721
Was this page helpful?