NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.
Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.
An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
A Computational and Experimental Investigation of Thermal Desorption and Vapor Sampling in an Explosive Trace Detector
Published
Author(s)
Matthew E. Staymates, Wayne Smith, Eric S. Windsor
Abstract
Swipe-based explosive trace detectors rely on thermal desorption to vaporize explosive particles collected on a swipe. The vaporized material is carried by air flows from the desorption unit to the inlet of the chemical analyzer, typically an ion mobility spectrometer. We have observed that the amount of explosives detected from a swipe varies with the location at which the explosives are collected on the swipe. There are two issues which may contribute to this effect: inhomogeneous or insufficient heating of the swipe during desorption and low velocity air flows that poorly transport desorbed vapor during the instruments analysis time. To better characterized this effect, we have simulated the air movements within a generic desorption unit using commercially available computational fluid dynamics software. Simulations are three dimensional, symmetric and solved under steady, laminar flow conditions. The calculated velocity field correlates directly with experimental detector response with the high explosive RDX. Results suggest that the limiting factor in this generic thermal desorption unit is not heating the swipe to a sufficient temperature, but the flow-field around the swipe and flow rate into the detector. Buoyancy effects due to heating dominate the flow-field and produce a vertical bulk fluid motion within the domain which opposes much of the flow drawn into the analyzer.
Citation
Journal of Fluids Engineering-Transactions of the Asme
Staymates, M.
, Smith, W.
and Windsor, E.
(2011),
A Computational and Experimental Investigation of Thermal Desorption and Vapor Sampling in an Explosive Trace Detector, Journal of Fluids Engineering-Transactions of the Asme
(Accessed October 4, 2025)