Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Comparison of Electrical CD Measurements and Cross-Section Lattice-Plane Counts of Sub-Micrometer Features Replicated in (100) Silicon-on-Insulator Material

Published

Author(s)

Michael W. Cresswell, John E. Bonevich, T J. Headley, Richard A. Allen, Lucille A. Giannuzzi, Sarah C. Everist, Rathindra Ghoshtagore, Patrick J. Shea

Abstract

Test structures of the type known as cross-bridge resistors have been patterned in (100) epitaxial silicon material that was seeded on Bonded and Etched-Back silicon-on-Insulator (BESOI) substrates. The electrical CDs (Critical Dimensions) of a limited selection of their reference segments have been measured electrically, by SEM (Scanning-Electron Microscopy) cross-section imaging, and by lattice-plane counting. The lattice-plane counting is achieved by High-Resolution Transmission-Electron Microscopy (HRTEM). The reference-segment features were aligned with <110> directions in the BESOI surface material and were defined by a silicon micro-machining process which resulted in their having atomically-planar and smooth (111) sidewalls inclined at 45.7370 to the substrate surface. This (100) implementation may complement the attributes of the previously-reported vertical-sidewall one for selected reference-material applications. The comparison of the offsets between the HRTEM and ECD linewidth measurements that are made on the same BESOI features is being investigated to determine the feasibility of a CD traceability path at acceptable cost. Other novel aspects of the (100) SOI implementation that are reported here are the ECD test-structure architecture and the making of HRTEM lattice-plane counts from both feature cross-sectional, as well as top-down, imaging of the reference features. This paper describes the design details, the fabrication, and the electrical testing, of the cross-bridge resistor test structure. The long-term goal is to develop a technique for determination of the absolute dimensions of the symmetrical trapezoidal cross-sections of the bridges' reference segments as a prelude to making them available for dimensional reference applications.
Volume
3998
Conference Location
Gaithersburg, MD, USA
Conference Title
SPIE - The International Society for Optical Engineering

Keywords

calibration, CD-SEM measurements, cross-bridge resistor, electrical CD, HRTEM, silicon-on-insulator, standards, traceability

Citation

Cresswell, M. , Bonevich, J. , Headley, T. , Allen, R. , Giannuzzi, L. , Everist, S. , Ghoshtagore, R. and Shea, P. (2000), Comparison of Electrical CD Measurements and Cross-Section Lattice-Plane Counts of Sub-Micrometer Features Replicated in (100) Silicon-on-Insulator Material, SPIE - The International Society for Optical Engineering, Gaithersburg, MD, USA (Accessed December 12, 2024)

Issues

If you have any questions about this publication or are having problems accessing it, please contact reflib@nist.gov.

Created May 31, 2000, Updated October 12, 2021