NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.
Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.
An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
Comparison of High- and Low-Voltage X-Ray Mapping of an Electronic Device
Published
Author(s)
John A. Small, David S. Bright
Abstract
In recent years, field-emission gun scanning electron microscopes, FEG-SEMs, with high-brightness electron guns and excellent performance at low electron beam energies (E0 less then or equal to 5 keV) have become readily available. Concurrently the performance of solid-state x-ray detectors such as the Si-Li detector has improved significantly and with the addition of ultra-thin window materials these devices are easily capable of detecting characteristic x-rays with energies as low as 150 eV. In conventional x-ray mapping the energy of the electron-beam is usually 15-25 keV and the maps are acquired with the K, L, and M shell x-ray lines with energies from 1 to 15 keV. At these electron beam energies, the lateral resolution of the x-ray maps is on the order of 1-3 mm. Reducing the electron beam energy to 5 keV or below and utilizing the K, L, and M lines with energies from 400 eV to 4 keV should significantly improve the lateral resolution of the x-ray maps. In this study, x-ray maps were acquired for Si-K x-rays at 1.74 keV and O-K x-ray at 0.53 keV on a Poly Si gate region of a CMOS device. The maps were acquired at a magnification of 70,000 diameters at beam energies of 15 and 5 keV. The 15 keV maps showed little or no variation in intensity corresponding to the device structure. In comparison, the intensity variation in the 5 keV maps correlated well with the Si and SiO2 features in the device. In addition the intensity profiles from the 5 keV maps were used to estimate the effective resolution of the Si and O maps at 160 and 130 nm respectively.
Proceedings Title
Characterization and Metrology for ULSI Technology, International Conference | | AIP Conference Proceedings #550 Characterization and Metrology for ULSI Technology 2000: International Conference | AIP
Volume
550
Conference Dates
June 26-29, 2000
Conference Title
AIP Conference Proceedings
Pub Type
Conferences
Keywords
electron beam, electron probe microanalysis, low-voltage x-rays, scanning electron microscopy, x-ray mapping, x-ray microanalysis
Citation
Small, J.
and Bright, D.
(2001),
Comparison of High- and Low-Voltage X-Ray Mapping of an Electronic Device, Characterization and Metrology for ULSI Technology, International Conference | | AIP Conference Proceedings #550 Characterization and Metrology for ULSI Technology 2000: International Conference | AIP
(Accessed October 8, 2025)