Skip to main content

NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.

Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.

U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

NIST/SEMATECH Collaboration: Application of Nano-Tips to Production CD-SEMs

Published

Author(s)

Andras Vladar, Michael T. Postek

Abstract

This work documents the first part of a two-part study about the application of nano-tips to critical dimension (CD) scanning electron microscopes used in integrated circuit production.  Nano-tips, by comparison to all conventional cold, thermally assisted and Schottky field emitters, offer a substantial increase in brightness and large reduction in source size.  This could provide a significant improvement in current CD-SEM technology and help to extend it beyond the 180-nm technology.  In an optimized electron optical column, the substitution of conventional field emitter electron source by a nano-tip is also expected to produce higher beam currents into a spot of given size.  This improvement is a consequence both of the increase in electron source brightness and because the smaller source size allows the use of a lower demagnification, resulting in a higher fraction of the gun emission reaching the final beam spot.  The work in the first part of this study included the preparation of a CD-SEM, the theoretical assessment of the gun and the electron optical column, the modifications needed for the new nano-tips and the design and implementation of a measuring system that allows for adequate measurements.  The results of the first of this portion of the study indicated that using a sharp-tip as an intermediate to the nano-tip an improvement in the performance of a CD-SEM can be clearly demonstrated.  This and the results of the theoretical assessement give support for the installation of the nano-tips and points to even better performance.
Citation
NIST/SEMATECH Collaboration LITG 410I Project Final Report

Keywords

critical dimension, field emission, nano-tips, scanning electron microscope, SEM Sentinel, sharp-tips

Citation

Vladar, A. and Postek, M. (2000), NIST/SEMATECH Collaboration: Application of Nano-Tips to Production CD-SEMs, NIST/SEMATECH Collaboration LITG 410I Project Final Report (Accessed October 1, 2025)

Issues

If you have any questions about this publication or are having problems accessing it, please contact [email protected].

Created November 15, 2000, Updated February 19, 2017
Was this page helpful?