NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.
Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.
An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
Lessons From the NIST Micronutrients Quality Assurance Program for Vitamin C, 1993 to 2015: Sample Stability, Assay Reproducibility, and Use of Controls to Improve Comparability
Published
Author(s)
David L. Duewer, Jeanice M. Brown Thomas, Katherine E. Sharpless, S A. Margolis
Abstract
Vitamin C is a necessary micronutrient that is involved in many biological processes. In preserved human plasma and serum, vitamin C is most meaningfully analyzed as total ascorbic acid (TAA). From 1993 through 2015, the National Institute of Standards and Technology (NIST) coordinated 40 interlaboratory studies (ILS) devoted to improving the between-participant comparability of TAA measurements. The results from these ILS demonstrate that the concentration TAA ([TAA]) is stable for at least 20 years in serum diluted 1+1 (volume fraction) with 10 % mass concentration aqueous metaphosphoric acid (MPA) and stored at −80 °C. The between-participant relative reproducibility precision, expressed as a coefficient of variation (CV), improved from over 16 % to under 9 % over the course of the studies. Normalization of test samples (i.e., ex past-facto recalibrating the as-submitted results) using participant-prepared serum-free calibration solutions did not improve reproducibility. Normalization to one control sample having a similar serum-based matrix as the test samples improved the CV to 7 %; normalization to two such controls reduced the CV to 4 %. Multicenter studies that require the highest degree of measurement comparability among the participants should consider calibrating with materials that have a serum-based matrix as similar as possible to that of the samples of interest.
Duewer, D.
, Brown, J.
, Sharpless, K.
and Margolis, S.
(2020),
Lessons From the NIST Micronutrients Quality Assurance Program for Vitamin C, 1993 to 2015: Sample Stability, Assay Reproducibility, and Use of Controls to Improve Comparability, Analytical and Bioanalytical Chemistry, [online], https://doi.org/10.1007/s00216-020-03021-9
(Accessed November 3, 2025)