Skip to main content

NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.

Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.

U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Effects of incomplete light extinction in frequency-agile, rapid scanning spectroscopy

Published

Author(s)

David Long, S. Wojtewicz, Joseph T. Hodges

Abstract

The effect of finite beam extinction ratio on the precision and accuracy of cavity ring-down decay time constant measurements was examined using the frequency-agile, rapid scanning, cavity ring-down spectroscopy (FARS-CRDS) technique. This new approach to CRDS uses a waveguide-based electro-optic phase modulator (EOM) to provide a laser beam extinction ratio as high as 80 dB: a value that is ≈30 dB greater than that typically achieved with acousto-optic-modulator-based beam switches. We find that the observed measurement precision scales inversely with extinction ratio, such that an EOM enables measurement of the cavity ring-down decay time with a relative precision of ≈8×10-5. We demonstrate that insufficient extinction can be the dominant cause of statistical uncertainty for extinction ratios below 60 dB. Furthermore, insufficient extinction can result in non-exponential decays, which cause systematic measurement biases in cavity losses and absorption.
Citation
SPIE Proceedings 2013 Defense Security and Sensing Conference

Keywords

cavity ring-down spectroscopy, optical switch, electro-optic phase modulator

Citation

Long, D. , Wojtewicz, S. and Hodges, J. (2013), Effects of incomplete light extinction in frequency-agile, rapid scanning spectroscopy, SPIE Proceedings 2013 Defense Security and Sensing Conference, [online], https://doi.org/10.1117/12.2016056, https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=913765 (Accessed October 10, 2025)

Issues

If you have any questions about this publication or are having problems accessing it, please contact [email protected].

Created July 31, 2013, Updated October 12, 2021
Was this page helpful?