Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Technical Note 1603 Explanation

Experimental Study of the Effects of Fuel Type, Fuel Distributions, and Vent Size on Full-Scale Underventilated Compartment Fires in an ISO 9705 Room

This is an explanation of the variable names used in the data files.

Variable Name Explanation
Time Time from the ignition of the fire
O2Front

Dry Oxygen volume fraction at front sample location

CO2Front Dry Carbon Dioxide volume fraction at front sample location
COFront Dry Carbon Monoxide volume fraction at front sample location
UHFront Dry Unburnt Hydrocarbon volume fraction at front sample location
TFSampPtRh Temperature in degrees Celsius of bare bead Type R Thermocouple at front sample location
O2Rear Dry oxygen volume fraction at rear sample location
CO2Rear Dry Carbon Dioxide volume fraction at rear sample location
CORear Dry Carbon Monoxide volume fraction at rear sample location
UHRear Dry Unburnt Hydrocarbon volume fraction at rear sample
TRSampPtRh Temperature in degrees Celsius of bare bead Type R Thermocouple at rear sample location
O2Move Dry Oxygen volume fraction at the movable probe location
CO2Move Dry Carbon Dioxide volume fraction at the movable probe location
COMove Dry Carbon Monoxide volume fraction at the movable probe location
UHMove Dry Unburnt Hydrocarbon volume fraction at the movable probe location
TRMoveSamp Temperature in degrees Celsius of aspirated Type K thermocouple at movable probe location
Zmove Vertical location of the movable sample probe
HFRFL Heat Flux in kW/m^2 at the rear floor location
HFFFL Heat Flux in kW/m^2 at the front floor location
HFOFL Heat Flux in kW/m^2 outside the door of the enclosure
HFRCE Heat Flux in kW/m^2 at the rear ceiling location
HFCCE Heat Flux in kW/m^2 at the center ceiling location
HFFCE Heat Flux in kW/m^2 at the front ceiling location
THFRFL Temperature of the Heat Flux gauge in degrees Celsius at the rear floor location
THFFFL Temperature of the Heat Flux gauge in degrees Celsius in the front floor location
THFOFL Temperature of the Heat Flux gauge in degrees Celsius outside the door of the enclosure
THFRCE Temperature of the Heat Flux gauge in degrees Celsius at the rear ceiling location
THFCCE Temperature of the Heat Flux gauge in degrees Celsius at the center ceiling location
THFFCE Temperature of the Heat Flux gauge in degrees Celsius at the front ceiling location
TSHFRFL Temperature of the enclosure surface near the Heat Flux gauge in degrees Celsius at the rear floor location
TSHFFFL Temperature of the enclosure surface near the Heat Flux gauge in degrees Celsius at the front floor location
TSHFOFL Temperature of the enclosure surface near the Heat Flux gauge in degrees Celsius outside the door of the enclosure
TSHFRCE Temperature of the enclosure surface near the Heat Flux gauge in degrees Celsius at the rear ceiling location
TSHFCCE Temperature of the enclosure surface near the Heat Flux gauge in degrees Celsius at the center ceiling location
TSHFFCE Temperature of the enclosure surface near the Heat Flux gauge in degrees Celsius at the front ceiling location
TSXHFRFL Temperature of the external enclosure surface near the Heat Flux gauge in degrees Celsius at the rear floor location
TSXHFFFL Temperature of the external enclosure surface near the Heat Flux gauge in degrees Celsius at the front floor location
TSXHFRCE Temperature of the external enclosure surface near the Heat Flux gauge in degrees Celsius at the rear ceiling location
TSXHFCCE Temperature of the external enclosure surface near the Heat Flux gauge in degrees Celsius at the center ceiling location
TSXHFFCE Temperature of the external enclosure surface near the Heat Flux gauge in degrees Celsius at the front ceiling location
Mass1 Mass measurement of pan burner at position 1 (center of room)
Mass2 Mass measurement of pan burner at position 2 (rear center of room)
TR3 Temperature in degrees Celsius of bare bead Type K thermocouple in rear thermocouple tree at 3 cm above the floor
TR30 Temperature in degrees Celsius of bare bead Type K thermocouple in rear thermocouple tree at 30 cm above the floor

TR60

Temperature in degrees Celsius of bare bead Type K thermocouple in rear thermocouple tree at 60 cm above the floor
TR90 Temperature in degrees Celsius of bare bead Type K thermocouple in rear thermocouple tree at 90 cm above the floor
TR105 Temperature in degrees Celsius of bare bead Type K thermocouple in rear thermocouple tree at 105 cm above the floor
TR120 Temperature in degrees Celsius of bare bead Type K thermocouple in rear thermocouple tree at 120 cm above the floor
TR135 Temperature in degrees Celsius of bare bead Type K thermocouple in rear thermocouple tree at 135 cm above the floor
TR150 Temperature in degrees Celsius of bare bead Type K thermocouple in rear thermocouple tree at 150 cm above the floor
TR180 Temperature in degrees Celsius of bare bead Type K thermocouple in rear thermocouple tree at 180 cm above the floor
TR210 Temperature in degrees Celsius of bare bead Type K thermocouple in rear thermocouple tree at 210 cm above the floor
TR237 Temperature in degrees Celsius of bare bead Type K thermocouple in rear thermocouple tree at 237 cm above the floor
TF3 Temperature in degrees Celsius of bare bead Type K thermocouple in front thermocouple tree at 3 cm above the floor
TF30 Temperature in degrees Celsius of bare bead Type K thermocouple in front thermocouple tree at 30 cm above the floor
TF60 Temperature in degrees Celsius of bare bead Type K thermocouple in front thermocouple tree at 60 cm above the floor
TF90 Temperature in degrees Celsius of bare bead Type K thermocouple in front thermocouple tree at 90 cm above the floor
TF105 Temperature in degrees Celsius of bare bead Type K thermocouple in front thermocouple tree at 105 cm above the floor
TF120 Temperature in degrees Celsius of bare bead Type K thermocouple in front thermocouple tree at 120 cm above the floor
TF135 Temperature in degrees Celsius of bare bead Type K thermocouple in front thermocouple tree at 135 cm above the floor
TF150 Temperature in degrees Celsius of bare bead Type K thermocouple in front thermocouple tree at 150 cm above the floor
TF180 Temperature in degrees Celsius of bare bead Type K thermocouple in front thermocouple tree at 180 cm above the floor
TF210 Temperature in degrees Celsius of bare bead Type K thermocouple in front thermocouple tree at 210 cm above the floor
TF237 Temperature in degrees Celsius of bare bead Type K thermocouple in front thermocouple tree at 237 cm above the floor
CalCo Dry Carbon Dioxide volume fraction at the calorimetry measurement in the hood
CalCO2 Dry Carbon Monoxide volume fraction at the calorimetry measurement in the hood
CalO2 Dry Oxygen volume fraction at the calorimetry measurement in the hood
IHRR Complete combustion heat release rate in kW based on the liquid pump flow rate for sprayed liquid fuels gas flow meter for gaseous fuels and mass loss rate for solid fuels and liquid fuels burned in a pan.
HRR2 Measured Heat Release Rate in kW
YsootF Wet Soot mass fraction at the front sample location
zloc Location in Z-direction in cm of movable probe at any given time.
 

Created January 6, 2012, Updated January 6, 2017