Experiment Name | Plot of Heat Release Rate | Ignition Photo | Date/Time | Project | Specimen Sort descending | Fuel Type | Total Heat Released (MJ) | Peak HRR (kW) |
---|---|---|---|---|---|---|---|---|
Test56_HIPS_R4 | Vertical Upward Flamespread on Parallel Panels | 1/4" thick, 24" wide, 96" tall panels of HIPS | High Impact Polystyrene (HIPS) | 513
|
3,173
|
|||
Test52_HIPS_R3 | Vertical Upward Flamespread on Parallel Panels | 1/4" thick, 24" wide, 96" tall panels of HIPS | High Impact Polystyrene (HIPS) | 535
|
3,094
|
|||
Test29_Kydex_R1 | Vertical Upward Flamespread on Parallel Panels | 1/4" thick, 24" wide, 96" tall panels of Kydex | Kydex (PVC-acrylic copolymer) | 111
|
1,060
|
|||
Test30_Kydex_R2 | Vertical Upward Flamespread on Parallel Panels | 1/4" thick, 24" wide, 96" tall panels of Kydex | Kydex (PVC-acrylic copolymer) | 182
|
1,070
|
|||
Test12_PBT_R1 | Vertical Upward Flamespread on Parallel Panels | 1/4" thick, 24" wide, 96" tall panels of PBT | Polybutylene terephthalate (PBT) | 375
|
2,821
|
|||
Test61_POMGF_R3 | Vertical Upward Flamespread on Parallel Panels | 1/4" thick, 24" wide, 96" tall panels of POM-GF | Polyoxymethylene (POM-GF) | 452
|
536
|
|||
Test28_POMGF_R1 | Vertical Upward Flamespread on Parallel Panels | 1/4" thick, 24" wide, 96" tall panels of POM-GF | Polyoxymethylene (POM-GF) | 387
|
503
|
|||
Test50_POMGF_R2 | Vertical Upward Flamespread on Parallel Panels | 1/4" thick, 24" wide, 96" tall panels of POM-GF | Polyoxymethylene (POM-GF) | 367
|
540
|
|||
Test11_PVC_R1 | Vertical Upward Flamespread on Parallel Panels | 1/4" thick, 24" wide, 96" tall panels of PVC | Polyvinyl chloride (PVC) | 61.9
|
163.2
|
|||
Test13_PVC_R2 | Vertical Upward Flamespread on Parallel Panels | 1/4" thick, 24" wide, 96" tall panels of PVC | Polyvinyl chloride (PVC) | 84.0
|
236
|
|||
Test64_XPSgreen2_R3 | Vertical Upward Flamespread on Parallel Panels | 2" thick, 24" wide, 96" tall panels of Green XPS Foam | Extruded Polystyrene Foam (XPS) | 97.8
|
1,426
|
|||
Test55_XPSgreen2_R2 | Vertical Upward Flamespread on Parallel Panels | 2" thick, 24" wide, 96" tall panels of Green XPS Foam | Extruded Polystyrene Foam (XPS) | 110
|
1,839
|
|||
Test42_XPSGreen2_R1 | Vertical Upward Flamespread on Parallel Panels | 2" thick, 24" wide, 96" tall panels of Green XPS Foam | Extruded Polystyrene Foam (XPS) | 105
|
1,946
|
|||
Test63_XPSpink2_R3 | Vertical Upward Flamespread on Parallel Panels | 2" thick, 24" wide, 96" tall panels of Pink XPS Foam | Extruded Polystyrene Foam (XPS) | 93.2
|
1,580
|
|||
Test54_XPSpink2_R2 | Vertical Upward Flamespread on Parallel Panels | 2" thick, 24" wide, 96" tall panels of Pink XPS Foam | Extruded Polystyrene Foam (XPS) | 84.5
|
1,510
|
|||
Test41_XPSPink2_R1 | Vertical Upward Flamespread on Parallel Panels | 2" thick, 24" wide, 96" tall panels of Pink XPS Foam | Extruded Polystyrene Foam (XPS) | 100.6
|
1,687
|
|||
Test27_Polyiso2_R2 | Vertical Upward Flamespread on Parallel Panels | 2" thick, 24" wide, 96" tall panels of Polyisocyanurate Foam | Polyisocyanurate Foam (foil-backed) | 38.8
|
801
|
|||
Test26_Polyiso2_R1 | Vertical Upward Flamespread on Parallel Panels | 2" thick, 24" wide, 96" tall panels of Polyisocyanurate Foam | Polyisocyanurate Foam (foil-backed) | 37.6
|
784
|
|||
Test20_OSB_R1 | Vertical Upward Flamespread on Parallel Panels | 7/16" thick, 24" wide, 96" tall panels of OSB | Oriented Strand Board (OSB) | 243
|
622
|
|||
Test37_OSB_R2 | Vertical Upward Flamespread on Parallel Panels | 7/16" thick, 24" wide, 96" tall panels of OSB | Oriented Strand Board (OSB) | 243
|
894
|
Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019
https://doi.org/10.6028/NIST.TN.2077
NIST Fire Calorimetry Database (FCD)
https://doi.org/10.18434/mds2-2314