Test16_8woodCrib_r1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Multiple Item Transient Combustion Calorimetry wood cribs Cellulose
5,120
2,301
15minRamp_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Steel-Concrete Composite Floor Systems Subject to Fire, Phase 2 Four square burners Natural Gas
5,047
8,034
15minRamp_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Steel-Concrete Composite Floor Systems Subject to Fire, Phase 2 Four square burners Natural Gas
4,850
7,980
NGQC_9m_50kgs_8MWa
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner tube gas burner Natural Gas
4,832
8,337
NGQC_9m_50kgs_8MW_R3pos
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner Tube Burner Natural Gas
4,816
8,413
OSB04b_ISOFire
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Kitchen Room Fire Box Burner with Target Wall Natural Gas
4,803
2,156
NGQC_9m_25kgs_5MW
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner tube burner Natural Gas
4,235
5,141
1B-PVSh0
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Structure Separation Experiments: Shed Burns without Wind HDPE Shed Wood Cribs HDPE and Cellulose
4,197
6,024
SB04b_ISOFire
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Kitchen Room Fire Box Burner with Target Wall Natural Gas
4,167
1,402
NGQC_9m_50kgs_8MW
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner tube gas burner Natural Gas
4,064
8,454
NGQC_15m_75kgs_12MW
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner tube gas burner Natural Gas
3,844
8,243
1B-WVSh0
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Structure Separation Experiments: Shed Burns without Wind Wood Shed Wood Cribs Cellulose
3,178
4,759
Test_3
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Room Flashover Experiments to Demonstrate the Effectiveness of Barrier Fabrics furnished room with cotton fabric sofa no barrier Cellulose, Plastic
2,636
9,639
Test_1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Room Flashover Experiments to Demonstrate the Effectiveness of Barrier Fabrics furnished room with polyester fabric sofa no barrier Cellulose, Plastic
2,551
9,175
Test15_4woodCrib_r1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Multiple Item Transient Combustion Calorimetry wood cribs Cellulose
2,523
1,402
NGQC_6m_20kgs_3MW
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner tube gas burner Natural Gas
2,462
3,140
NGQC_6m_20kgs_3MW
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Multiple Item Transient Combustion Calorimetry tube gas burner Natural Gas
2,372
3,094
NGQC_6m_20kgs_3MW
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner tube gas burner Natural Gas
2,372
3,094
Test_2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Room Flashover Experiments to Demonstrate the Effectiveness of Barrier Fabrics furnished room with cotton fabric sofa with barrier Cellulose, Plastic
2,246
8,422
Test8_8Pallet_r1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Multiple Item Transient Combustion Calorimetry wood pallets and paper Cellulose
2,229
4,174