1B-PVSh0

Table 1. Test Information
Name
1B-PVSh0
Date
Description

Shed only test with High Density Polyethylene shed (61.426 kg) high fuel load: wood cribs (6 x 1A) (114.4 kg) 300mL Heptane

Specimen
HDPE Shed Wood Cribs
Ignition
heptane pan
Project ID (s)
Test Director
Maranghides A

Timelapse Video with Heat Release Rate Plot

Table 2. Summary of Test Results
Measurement Value Uc Unit
Peak Heat Release Rate, PHRR
6,024
306
kW
Time to Peak Heat Release Rate
8.47
0.17
min
Total Heat Released, THR
4,197
228
MJ
Natural Gas Burner Total Heat Released, NGTHR
-3
-
MJ
Heat Release Quality Confirmation, HRQC
Not measured -
MJ/MJ
Net Specimen Mass (gravimetric), NM = Mi-Mf
Not measured -
kg
Total Fuel Mass Burned, TFM = THR / HOCf
157.2
9.8
kg
Net Effective Heat of Combustion = THR / NM
Not measured -
MJ/kg
O2 Yield = O2 Consumed / TFM
1.92
0.13
kg/kg
CO2 Yield = CO2 Generated / TFM
2.16
0.16
kg/kg
CO Yield = CO Generated / TFM
0.0187
0.0013
kg/kg
Soot Yield = Soot Generated / TFM
0.0128
0.0023
kg/kg
Baseline Hood Exhaust Flow
44.5
1.3
kg/s
Test Duration = Time(Fire Out) - Time(Ignition)
71.30
0.03
min

Uc = Combined Expanded Uncertainty with 95% confidence level

Table 3. Summary of Test Input Parameters
Parameter Value Uc Unit
Fuel Type
HDPE and Cellulose
- -
Hood Size
9
-
m
Effective Duct Diameter
1.975
0.005
m
Exhaust Flow Correction Factor
1.055
0.034
-
Net Heat of Combustion (per unit mass O2), Ef
13.61
0.54
MJ/kg
Net Heat of Combustion(per unit mass fuel), HOCf
26.70
0.80
MJ/kg
Initial Specimen Mass, Mi (gravimetric)
175.83
0.02
kg
Final Specimen Mass, Mf (gravimetric)
Not measured -
kg
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Figure 1. Plot of Heat Release Rate data with event markers and error bars shown at peak.
Table 4. Summary of Observed Test Events
Event Time (min) Description Video Snapshot Image
1
0.00
Ignition
Ignition
peak
8.47
Peak HRR
Peak HRR
2
40.03
stir ember pile in pan
stir ember pile in pan
3
60.07
water suppression
water suppression
4
65.17
Ember recovery in progress
Ember recovery in progress
5
71.30
Fire Out
Fire Out

Table 5. Supplemental Data Plots

Plot of Oxygen Dry Volume Fraction in hood exhaust stream.
Plot of Oxygen Dry Volume Fraction in hood exhaust stream.
Plot of Carbon Dioxide Dry Volume Fraction in hood exhaust stream.
Plot of Carbon Dioxide Dry Volume Fraction in hood exhaust stream.
Plot of Carbon Monoxide Dry Volume Fraction in hood exhaust stream.
Plot of Carbon Monoxide Dry Volume Fraction in hood exhaust stream.
Plot of Radiant Heat Flux data with event markers. r= radial distance from center of hood, h=height above floor.
Plot of Radiant Heat Flux data with event markers. r= radial distance from center of hood, h=height above floor.
Plot of Smoke Laser Extinction Coefficient in hood exhaust stream.
Plot of Smoke Laser Extinction Coefficient in hood exhaust stream.
Plot of Exhaust Duct Mass Flow Rate.
Plot of Exhaust Duct Mass Flow Rate.

Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019
https://doi.org/10.6028/NIST.TN.2077

NIST Fire Calorimetry Database (FCD)
https://doi.org/10.18434/mds2-2314

Report Process Script Version
NFRL_Report_8.4.6