Experiment Name | Plot of Heat Release Rate | Ignition Photo | Date/Time | Project | Specimen | Fuel Type Sort descending | Total Heat Released (MJ) | Peak HRR (kW) |
---|---|---|---|---|---|---|---|---|
B2-1 | Fire Barriers in Full-Scale Chair Mock-ups | upholstered chair mockup | Polyurethane Foam | 314
|
2,320
|
|||
B1-2 | Fire Barriers in Full-Scale Chair Mock-ups | upholstered chair mockup | Polyurethane Foam | 313
|
1,063
|
|||
C0-2 | Fire Barriers in Full-Scale Chair Mock-ups | upholstered chair mockup | Polyurethane Foam | 325
|
2,697
|
|||
Control-Smoldering | Fire Barriers in Full-Scale Chair Mock-ups | upholstered chair mockup | Polyurethane Foam | below detection limit
|
9.4
|
|||
C0-3 | Fire Barriers in Full-Scale Chair Mock-ups | upholstered chair mockup | Polyurethane Foam | 321
|
2,517
|
|||
Test13_PVC_R2 | Vertical Upward Flamespread on Parallel Panels | 1/4" thick, 24" wide, 96" tall panels of PVC | Polyvinyl chloride (PVC) | 84.0
|
236
|
|||
Test11_PVC_R1 | Vertical Upward Flamespread on Parallel Panels | 1/4" thick, 24" wide, 96" tall panels of PVC | Polyvinyl chloride (PVC) | 61.9
|
163.2
|
|||
Propane Burner Check | Fire Barriers in Full-Scale Chair Mock-ups | gas tube burner | Propane | 3.22
|
24.3
|
|||
BurnerShakedown21 | Vertical Upward Flamespread on Parallel Panels | Sand Burner | Propane | 22.9
|
71.0
|
|||
BurnerShakedown27 | Vertical Upward Flamespread on Parallel Panels | Sand Burner | Propane | 22.7
|
70.7
|
|||
BurnerShakedownO1 | Vertical Upward Flamespread on Parallel Panels | sand burner box | Propane | 37.7
|
71.2
|
|||
Test030_GardenHose_R1 | Transient Combustion Calorimetry (TCC) | Rubber hose | Rubber | 41.8
|
24.9
|
|||
Test082_GardenHose_R2 | Transient Combustion Calorimetry (TCC) | Rubber hose | Rubber | 0.48
|
1.40
|
|||
Test083_GardenHose_R3 | Transient Combustion Calorimetry (TCC) | Rubber hose | Rubber | 0.68
|
1.57
|
|||
Test22_RedCedar_R2 | Vertical Upward Flamespread on Parallel Panels | 7/8" thick, 22.5" wide, 96" tall planks of Western Red Cedar | Western Red Cedar | 44.4
|
322
|
|||
Test43_RedCedar_R3 | Vertical Upward Flamespread on Parallel Panels | 7/8" thick, 22.5" wide, 96" tall planks of Western Red Cedar | Western Red Cedar | 38.8
|
398
|
|||
Test65_RedCedar_R4 | Vertical Upward Flamespread on Parallel Panels | 7/8" thick, 22.5" wide, 96" tall planks of Western Red Cedar | Western Red Cedar | 65.1
|
378
|
|||
Test15_RedCedar_R1 | Vertical Upward Flamespread on Parallel Panels | 7/8" thick, 22.5" wide, 96" tall planks of Western Red Cedar | Western Red Cedar | 139
|
307
|
|||
Test9_SIS_wire_R1 | Vertical Upward Flamespread on Parallel Panels | 90 vertically oriented strands of SIS wire | XLPE (SIS Wire) | 16.0
|
132.8
|
|||
Test10_SIS_wire_R2 | Vertical Upward Flamespread on Parallel Panels | 96 vertically oriented strands of SIS wire attached to 1/4" thick, 24" wide, 96"tall panels of GPO-3 | XLPE (SIS Wire) and (GPO-3) | 47
|
142
|
Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019
https://doi.org/10.6028/NIST.TN.2077
NIST Fire Calorimetry Database (FCD)
https://doi.org/10.18434/mds2-2314