Experiment Name Plot of Heat Release Rate Ignition Photo Date/Time Sort ascending Project Specimen Fuel Type Total Heat Released (MJ) Peak HRR (kW)
Test4_PMMA_R4
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels 1/4" thick, 24" wide, 96" tall panels of cast Black PMMA Polymethyl methacrylate (PMMA)
504
3,140
NGQC_6m_draftflow_250kW
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner Tube Burner Natural Gas
150.3
281.3
NGQC_6m_20kgs_3MW
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels tube gas burner Natural Gas
2,127
3,022
NGQC_6m_20kgs_3MW
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner tube gas burner Natural Gas
2,127
3,022
Test3_PMMA_R3
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels 1/4" thick, 24" wide, 96" tall panels of cast Black PMMA Polymethyl methacrylate (PMMA)
506
3,197
Test2_PMMA_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels 1/4" thick, 24" wide, 96" tall panels of cast Black PMMA Polymethyl methacrylate (PMMA)
506
2,882
NGQC_9m_40kgs_8MW
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner tube burner Natural Gas
5,203
9,151
NGQC_9m_25kgs_5MW
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner tube burner Natural Gas
4,235
5,141
NGQC_9m_50kgs_8MWa
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner tube gas burner Natural Gas
4,832
8,337
NGQC_3m_3kgs_500kW
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner box gas burner Natural Gas
381
532
Test1_PMMA_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels 1/4" thick, 24" wide, 96" tall panels of cast Black PMMA Polymethyl methacrylate (PMMA)
506
2,540
NG_Ver_2MW_16kgs
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner tube burner Natural Gas
1,329
2,050
60minRamp_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Steel-Concrete Composite Floor Systems Subject to Fire, Phase 2 Four square burners Natural Gas
37,631
10,317
15minRamp_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Steel-Concrete Composite Floor Systems Subject to Fire, Phase 2 Four square burners Natural Gas
4,850
7,980
15minRamp_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Steel-Concrete Composite Floor Systems Subject to Fire, Phase 2 Four square burners Natural Gas
5,047
8,034
Methanol_1m_Pool_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Characteristics of a 1 m Methanol Pool Fire 1 m diameter pool burner Methanol
1,243
279
Methanol_1m_Pool_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Characteristics of a 1 m Methanol Pool Fire 1 m diameter pool burner Methanol
753
282
NGCal_3mHood_300kW_2kgs
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner box gas burner Natural Gas
186.9
328
NGCal_3mHood_300kW_2kgs
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) box gas burner Natural Gas
186.9
328
NGCal_6m_3MW_16kgs
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Natural Gas Confirmation Burner tube gas burner Natural Gas
1,932
3,159

Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019
https://doi.org/10.6028/NIST.TN.2077

NIST Fire Calorimetry Database (FCD)
https://doi.org/10.18434/mds2-2314