Ultra Low Dark-count-rate Up-conversion Single Photon Detector
Published
Author(s)
Xiao Tang, Lijun Ma, Oliver T. Slattery
Abstract
We have demonstrated an ultra low noise up-conversion single photon detector using a periodically poled lithium niobate waveguide. The dark count rate of this detector is lower than 100 counts/second with 10% detection efficiency.
Proceedings Title
Proceedings of 2010 IEEE Photonics Society Annual Meeting
Conference Dates
November 7-11, 2010
Conference Location
Denver, CO
Conference Title
The 23rd Annual Meeting of the IEEE Photonics Society
Tang, X.
, Ma, L.
and Slattery, O.
(2010),
Ultra Low Dark-count-rate Up-conversion Single Photon Detector, Proceedings of 2010 IEEE Photonics Society Annual Meeting , Denver, CO, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=906177