A high resolution gamma-ray spectrometer based on superconducting microcalorimeters

September 28, 2012
Author(s)
Douglas A. Bennett, Robert D. Horansky, Daniel R. Schmidt, Andrew Hoover, Ryan Winkler, Bradley K. Alpert, James A. Beall, William B. Doriese, Joseph W. Fowler, Gene C. Hilton, Kent D. Irwin, Nathan J. Hoteling, Vincent Y. Kotsubo, John A. Mates, Galen C. O'Neil, Michael W. Rabin, Carl D. Reintsema, Francis J. Schima, Daniel S. Swetz, Leila R. Vale, Joel N. Ullom
Improvements in superconductor device fabrication, detector hybridization techniques, and superconducting quantum interference device readout have made square-centimeter-sized arrays of gammaray microcalorimeters, based on transition-edge sensors (TESs)

A High Resolution High-Sensitivity Standoff Imaging System at 350 GHz

May 23, 2011
Author(s)
Daniel T. Becker, Cale Gentry, James A. Beall, Hsiao-Mei Cho, William Duncan, Gene C. Hilton, Kent D. Irwin, Peter J. Lowell, Michael D. Niemack, Nicholas G. Paulter Jr., Carl D. Reintsema, Francis J. Schima, Robert E. Schwall, Peter Ade, Carole Tucker, Simon Dicker, Halpern Mark
Millimeter wavelength radiation holds promise for detection of security threats at a distance, including suicide bomb belts and maritime threats in poor weather conditions. The sensitivity provided by superconducting Transition-Edge-Sensor (TES) bolometers

A 350-GHz high-resolution high-sensitivity passive video imaging system

April 27, 2010
Author(s)
Daniel T. Becker, James A. Beall, Hsiao-Mei Cho, William Duncan, Kent D. Irwin, Gene C. Hilton, Robert D. Horansky, Peter J. Lowell, Michael D. Niemack, Nicholas G. Paulter Jr., Carl D. Reintsema, Francis J. Schima, Robert E. Schwall, Ki W. Yoon, Peter Ade, Carole Tucker, Simon Dicker, Mark Halpern
We are developing a 350 GHz cryogenic passive video imaging system. This demonstration system uses 800 photon-noise-limited superconducting transition edge sensor bolometers. It will image a 1 m x 1 m area at a standoff distance of 16 m to a resolution of

Optimal filtering, record length, and count rate in transition-edge-sensor microcalorimeters

December 16, 2009
Author(s)
William B. Doriese, Gene C. Hilton, Kent D. Irwin, Francis J. Schima, Joel N. Ullom, Joseph S. Adams, Caroline A. Kilbourne
In typical algorithms for optimally filtering transition-edge-sensor-microcalorimeter pulses, the average value of a filtered pulse is set to zero. The achieved energy resolution of the detector then depends strongly on the chosen length of the pulse