An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
https://www.nist.gov/publications/search
Search Publications
NIST Authors in Bold
Displaying 34001 - 34025 of 74421
Junctions using amorphous NbxSi1-x as a barrier have been developed for a wide range of possible applications. By co-sputtering the Nb and Si, both the relative composition and the barrier thickness can be independently controlled. As the Nb content
Ingrid E. Chesnick, Emiliano Fratini, Richard D. Leapman, William Landis, Naomi Eidelman, Kimberlee Potter
We present a three-dimensional mineralizing model based on a hollow fiber bioreactor (HFBR) inoculated with primary osteoblasts isolated from embryonic chick calvaria. Using non-invasive magnetic resonance microscopy (MRM), the growth and development of
Robert Hadfield, Jonathan L. Habif, John Schlafer, Robert E. Schwall, Sae Woo Nam
The authors report on the full implementation of a superconducting detector technology in a fiber-based quantum key distribution (QKD) link. Nanowire-based superconducting single-photon detectors (SSPDs) offer single-photon detection with low dark counts
Stephen Knight, Joaquin (. Martinez, Michele L. Buckley
The microelectronics industry supplies vital components to the electronics industry and to the U.S. economy, enabling rapid improvements in productivity and in new high technology growth industries such as electronic commerce and biotechnology. The
Jason Benkoski, Ronald L. Jones, Jack F. Douglas, Alamgir Karim
We present a novel platform for the creation of 2-D assemblies from nanoscale building blocks. The system consists of an oil/water interface in which the oil phase can be flash-cured upon UV exposure. The photopolymerizable material, 1,12-dodecanediol
M J. Tubergen, R L. Lavrich, David F. Plusquellic, R D. Suenram
Microwave spectra have been recorded for 1-phenyl-2-propanol, methamphetamine, and 1-phenyl-2-propanone in the range 11 GHz to 24 GHz using a Fourier-transform microwave spectrometer. Only one spectrum from a single conformational isomer was observed for
William Rippard, Matthew Pufall, Stephen E. Russek
We have measured the detailed dependence of the oscillation frequencies, linewidths, and output powers of spin-transfer nanocontact oscillators as functions of applied field strength, bias current, and angle of the applied magnetic field. For fields
We consider a two-state system driven by an on-resonance, continuous wave pump laser and a much weaker pulsed probe laser that is slightly detuned from the pump laser frequency usually this detuning is about p −P=1 kHz. The upper state population is
In previous work, several significant improvements in the measurement of distillation curves for complex fluids were introduced. The modifications to the classical measurement provide for (1) temperature and volume measurements of low uncertainty, (2)
Kristine A. Bertness, Alexana Roshko, Lorelle Mansfield, Todd E. Harvey, Norman Sanford
We have examined the initial steps for catalyst-free growth of GaN using molecular beam epitaxy on Si (111) substrates using AlN buffer layers. These wires form spontaneously under high N-to-Ga ratios for a growth temperature range of about 810 to 830 °C
W S. Yoon, Kyung Y. Chung, James McBreen, Daniel A. Fischer, Xiao-Qing Yang
The electronic structures of Li1-xNiO2 system after electrochemically delithiated to various x values have been investigated using soft X-ray absorption spectroscopy (XAS) for oxygen K-edge and Ni LII,III-edge. By comparing the O K-edge XAS spectra of Li1
By executing different fingerprint-image matching algorithms on large data sets, it reveals that the match and non-match similarity scores have no specific underlying distribution function. Thus, it requires a nonparametric analysis for fingerprint-image
A nonparametric inferential statistical data analysis is presented. The utility of this method is demonstrated through analyzing results from minutiae exchange with two-finger fusion. The analysis focused on high-accuracy vendors and two modes of matching
Dean M. DeLongchamp, Mang-Mang Ling, Youngsuk Jung, Daniel A. Fischer, Mark Roberts, Eric K. Lin, Zhenan Bao
The measurement and optimization of microstructure development in organic semiconductor films is valuable because microstructure in many cases critically impacts electronic performance. We demonstrate a general method to measure microstructure thickness
A study of spectra emitted by the quiet solar corona indicates that the majority of line intensities originating in low-lying levels are consistent with isothermal plasma of ~1.3 106 K. Nevertheless, a number of line intensities and in particular those
This survey provides a review of example off-the-shelf lift and wheelchair products on the market today. Also, it provides a review of example research in these areas including advancements in intelligent wheelchair designs and capabilities. We have
GPS carrier-phase frequency transfer (GPSCPFT) and two-way satellite time and frequency transfer (TWSTFT) were performed along three trans-Atlantic links over the six-month period 29 January ¿ 31 July 2006. The GPSCPFT and TWSTFT results were subtracted in
A new correlation for two-phase flow pressure drop in 180? return bends is proposed based on a total of 241 experimental data points for R-22 and R-410A from two independent studies. The data span smooth tubes with inner diameters (D) from 3.3 mm to 11.6
We examine the effects of the rooftop environment on GPS time transfer, in particular the effects of multipath reflections from nearby metallic objects. Three different antennas sites were selected on the roof of the NIST laboratories at Boulder, Colorado
The ionosphere-free code (P3) GPS time transfer uses the dual-frequency measurements from GPS geodetic receivers to minimize the errors in the ionospheric delay correction. The P3 GPS time transfer requires the knowledge of the receiver delays on both the
The problem of signal integrity for GPS satellites is discussed. In particular, there is a need for characterizing peak deviation of GPS clocks from prediction. Results from a preliminary study of two GPS clocks tested on the ground show that the
Svenja A. Knappe, V Shah, Vladislav Gerginov, Alan Brannon, Leo W. Hollberg, John E. Kitching
We present measurements regarding the long-term frequency instability of NIST CSAC physics packages. Changes of the clock frequency are caused mainly through time-dependent light shifts by the frequency-modulated VCSEL and properties of the vapor cell. We
NIST s role in providing the optical radiation measurement science and standards to ensure the quality, accuracy, and comparability of our Nation s remote sensing measurements in support of climate-change research is presented. Climate research has