Skip to main content

NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.

Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.

U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Multi-facility comparison of InGaAs trap detector responsivity for optical fiber power

Published

Author(s)

Kyle Rogers, Jeanne Houston, Zeus Ruiz Gutierrez, Matthew Spidell, Padraic Aither, Marty Gould, John Lehman

Abstract

The absolute responsivity of an optical detector in a trap configuration has been investigated in the interest of high-accuracy fiber-coupled measurements for commercial optical fiber power meters and fiber-coupled single-photon detector calibrations. The highest accuracy measurements of optical power are typically undertaken free space and then disseminated for fiber-coupled measurements with some additional uncertainty. At the lowest uncertainty, the difference between free-space and fiber-coupled optical power measurements can be significant. We present here a complete evaluation of multiple trap detectors consisting of two InGaAs photodiodes and a concave mirror. This evaluation includes fiber-based responsivity at discrete laser wavelengths measured both with cryogenic and room temperature standards (diverging input beam), free-space absolute spectral responsivity over a broad wavelength range (converging beam), free-space responsivity at discrete laser wavelengths (collimated), linearity, and spatial uniformity.
Citation
Metrologia
Volume
62

Keywords

trap detector, fiber optic power meter, laser power calibration

Citation

Rogers, K. , Houston, J. , Ruiz Gutierrez, Z. , Spidell, M. , Aither, P. , Gould, M. and Lehman, J. (2025), Multi-facility comparison of InGaAs trap detector responsivity for optical fiber power, Metrologia, [online], https://doi.org/10.1088/1681-7575/adfde4, https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=959919 (Accessed October 10, 2025)

Issues

If you have any questions about this publication or are having problems accessing it, please contact [email protected].

Created September 1, 2025, Updated September 2, 2025
Was this page helpful?