Multi-class steroid profiling in short-finned pilot whale blubber using liquid chromatography-tandem mass spectrometry (LC-MS/MS)

Published

Author(s)

Jillian Wisse, Douglas Nowacek, Ashley Russell

Abstract

Rationale: Wildlife scientists are quantifying steroid hormones in a growing number of tissue types and employing novel methods which must undergo validation before application. This study tested the accuracy and precision of liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods for use on blubber samples from short-finned pilot whales (Globicephala macrorhynchus). We expanded upon a method for corticosteroid quantification by increasing the number of analytes and matched internal standards used. Two analytes added to the method, aldosterone and DHEA, have not been previously quantified in whale blubber. Methods: We optimized a method for the quantification of seven steroid hormones using LC-MS/MS with a C18 column. We assessed the accuracy and precision of this updated C18 method and an existing Biphenyl method for their use with short-finned pilot whale blubber tissue by conducting a spike-recovery experiment and calculating percent recovery and RSD for each analyte. To explore the potential for running this method more cost-effectively with fewer matched internal standards (IS), we compared the performance of multiple internal standards for each analyte. Results: The C18 method produced reliable quantitation for the seven target adrenal steroids, including new additions, aldosterone and DHEA. The measurement of all 11 analytes was both accurate and precise, with percent recoveries between 82 % to 110 % and RSDs below 10 %. IS comparisons showed that 10 of 11 analytes could be calculated accurately and precisely with at least one of the IS substitutes. For one analyte, B, IS substitutes performed better than the B-d4 matched internal standard. Though many internal standard substitutions met percent recovery and RSD requirements, some of these substitutions significantly altered the analyte concentrations calculated. Discussion: The methods developed and tested in this study provide reliable detection and quantification of 11 steroid hormones, including DHEA, which has not been previously quantified in blubber. These methods can be used for more comprehensive assessments of adrenal and gonadal steroid hormones from free-ranging whales. Laboratories can reduce costs through IS substitution but should consider how these substitutions might affect results.
Citation
Rapid Communications in Mass Spectrometry

Keywords

Steroid hormones, Liquid chromatography-tandem mass spectrometry, Corticosteroids, Androgens, Progestogens

Citation

Wisse, J. , Nowacek, D. and Russell, A. (2025), Multi-class steroid profiling in short-finned pilot whale blubber using liquid chromatography-tandem mass spectrometry (LC-MS/MS), Rapid Communications in Mass Spectrometry, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=935603 (Accessed April 30, 2025)

Issues

If you have any questions about this publication or are having problems accessing it, please contact reflib@nist.gov.

Created March 30, 2025, Updated April 29, 2025