Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Metabolomics Test Materials for Quality Control: A Study of a Urine Materials Suite

Published

Author(s)

Dan Bearden, David A. Sheen, Yamil Simon, Bruce A. Benner Jr., Werickson Fortunato de Carvalho Rocha, Niksa Blonder, Katrice A. Lippa, Richard Beger, Laura Schnackenberg, Jinchun Sun, Khyati Mehta, Amrita Cheema, Haiwei Gu, Ramesh Marupaka, Nagana Gowda, Daniel Raftery

Abstract

There is a lack of experimental reference materials and standards for metabolomics measurements, such as urine, plasma, and other human fluid samples. Reasons include difficulties with supply, distribution, and dissemination of information about the materials. Additionally, there is a long lead time because reference materials need their compositions to be fully characterized with uncertainty, a labor-intensive process for material containing thousands of relevant compounds. Furthermore, data analysis can be hampered by different methods using different software by different vendors. In this work, we propose an alternative implementation of reference materials. Instead of characterizing biological materials based on their composition, we propose using untargeted metabolomic data such as nuclear magnetic resonance (NMR) or gas and liquid chromatography-mass spectrometry (GC-MS and LC-MS) profiles. The profiles are then distributed with the material accompanying the certificate, so that researchers can compare their own metabolomic measurements with the reference profiles. To demonstrate this approach, we conducted an interlaboratory study (ILS) in which seven National Institute of Standards and Technology (NIST) urine Standard Reference Material®s (SRM®s) were distributed to participants, who then returned the metabolomic data to us. We then implemented chemometric methods to analyze the data together to estimate the uncertainties in the current measurement techniques. The participants identified similar patterns in the profiles that distinguished the seven samples. Even when the number of spectral features is substantially different between platforms, a collective analysis still shows significant overlap that allows reliable comparison between participants. Our results show that a urine suite such as that used in this ILS could be employed for testing and harmonization among different platforms. A limited quantity of test materials will be made available for researc
Citation
Metabolites
Volume
9
Issue
11

Keywords

interlaboratory study, metabolomics, urine

Citation

Bearden, D. , Sheen, D. , Simon, Y. , Benner, B. , Fortunato, W. , Blonder, N. , Lippa, K. , Beger, R. , Schnackenberg, L. , Sun, J. , Mehta, K. , Cheema, A. , Gu, H. , Marupaka, R. , Gowda, N. and Raftery, D. (2019), Metabolomics Test Materials for Quality Control: A Study of a Urine Materials Suite, Metabolites, [online], https://doi.org/10.3390/metabo9110270 (Accessed October 13, 2024)

Issues

If you have any questions about this publication or are having problems accessing it, please contact reflib@nist.gov.

Created November 7, 2019, Updated April 27, 2020