Skip to main content

NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.

Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.

U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Magneto-resistive Field Mapping of Analog Audio Tapes for Forensics Imaging

Published

Author(s)

David P. Pappas

Abstract

Magneto-resistive imaging of cassette tapes for forensic analysis applications is presented. Sample tapes were recorded on various tape recorders with events typically encountered in investigations. A comparison of the images with those obtained using ferrofluid is presented, along with comparisons of multiple instances of the same event with the various recorders.
Proceedings Title
Audio Engineering Society 33rd Conference Proceedings
Conference Dates
June 4-7, 2008
Conference Location
Denver, CO

Keywords

Forensics, magnetic tape, magnetic imaging, Barber-pole sensor, magneto-resistor, sensor array

Citation

, D. (2008), Magneto-resistive Field Mapping of Analog Audio Tapes for Forensics Imaging, Audio Engineering Society 33rd Conference Proceedings, Denver, CO, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=32996 (Accessed October 14, 2025)

Issues

If you have any questions about this publication or are having problems accessing it, please contact [email protected].

Created June 1, 2008, Updated June 24, 2021
Was this page helpful?