Influence of Fire on the Shear Capacity of Steel-Sheathed Cold-Formed Steel Framed Shear Walls
Published
Author(s)
Matthew S. Hoehler, Blanca Andres Valiente
Abstract
This paper discusses experimental investigations of the influence of real fires on the lateral load-carrying capacity of steel-sheathed cold-formed steel framed shear walls. The completed Phase 1 tests showed an unexpected and important example of structure-fire interaction and highlight the relevance of the gypsum for both the thermal and mechanical behaviour of these systems. A second phase of the study currently underway is outlined, with focus given to the test program, specimen design and fire load development.
Proceedings Title
SiF18 - The 10th International Conference on Structures in Fire
Hoehler, M.
and Andres, B.
(2018),
Influence of Fire on the Shear Capacity of Steel-Sheathed Cold-Formed Steel Framed Shear Walls, SiF18 - The 10th International Conference on Structures in Fire, Belfast, -1, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=925555