Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Evaluation of viability and proliferation profiles on macrophages treated with silica nanoparticles in vitro via plate-based, flow cytometry, and Coulter counter assays

Published

Author(s)

Simona Bancos, De-Hao D. Tsai, Vincent A. Hackley, J L. Weaver, Katherine M. Tyner

Abstract

Nanoparticles (NPs) are known to interfere with many high throughput cell viability and cell proliferation assays, which complicates the assessment of their potential toxic effects. The aim of this study was to compare viability and proliferation results for colloidal silica (SiO2 NP; 7 nm) in the RAW 264.7 mouse macrophage cell line using three different techniques: plate-based assays, flow cytometry analysis, and Coulter counter assays. Our data indicate that CellTiter-Blue, XTT (2, 3-bis [2-methoxy-4-nitro-5-sulfophenyl]-2H-tetrazolium-5-carboxanilide) and CyQuant plate-based assays show increased values over control at low SiO2 NPs concentrations (0.001-0.01 g/L). SiO2 NPs show little to no interference with flow cytometry and Coulter Counter assays, which were not only more reliable in determining cell viability and proliferation at low concentration in vitro, but also identified changes in cell granularity and size that were not captured by the plate-based assays. At high SiO2 NP concentrations (1 g/L) all techniques indicated cytotoxicity. In conclusion, flow cytometry and Coulter counter identified new cellular features and flow cytometry offered more flexibility in analyzing the viability and proliferation profile of SiO2 NP-treated RAW 264.7 cells.
Citation
International Journal of Nanotechnology

Keywords

interference, nanoparticle, silica, size, viability

Citation

Bancos, S. , Tsai, D. , Hackley, V. , Weaver, J. and Tyner, K. (2012), Evaluation of viability and proliferation profiles on macrophages treated with silica nanoparticles in vitro via plate-based, flow cytometry, and Coulter counter assays, International Journal of Nanotechnology, [online], https://doi.org/10.5402/2012/454072, https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=911765 (Accessed March 29, 2024)
Created September 2, 2012, Updated October 12, 2021