Design and Correction Factor Evaluation of a WR-15 (50 to 75 GHz) Microcalorimeter

Published

Author(s)

Thomas P. Crowley, Xiaohai Cui

Abstract

The design and evaluation of a WR-15 (50 to 75 GHz) rectangular waveguide microcalorimeter is presented. This new microcalorimeter will be the national standard for power in the US from 50 to 75 GHz. It can measure the effective efficiency of a wider variety of transfer standards than the previous microcalorimeter. It has also been designed so that its correction factor can be experimentally evaluated using multiple techniques.
Proceedings Title
CPEM 2008
Conference Dates
June 8-13, 2008
Conference Location
Broomfield, CO
Conference Title
Conference on Precision Electromagnetic Measurements

Keywords

microcalorimeter, RF power, microwave power

Citation

Crowley, T. and Cui, X. (2008), Design and Correction Factor Evaluation of a WR-15 (50 to 75 GHz) Microcalorimeter, CPEM 2008, Broomfield, CO (Accessed April 25, 2024)
Created June 8, 2008, Updated January 27, 2020