Comparison of Radiated Emission Measurements for 500 MHz to 2 GHz in various EMC Facilities

Published

Author(s)

Marco Candidi, Christopher L. Holloway, Perry F. Wilson, Dennis G. Camell

Abstract

In this paper we present a comparison of radiated emission measurements from four test facilities (reverberation chamber, GTEM cell, OATS, and fully anechoic chamber)for two different devices. The use of a dipole model to correlate emission data between the OATS facility and the other three facilities, for both electrically small and electrically large test objects, is investigated. It is found that, for the emitters considered, the overall agreement between OATS data and correlated data is good, even for the electrically large test object case.
Conference Dates
September 9-13, 2002
Conference Location
Sorrento, 1, IT
Conference Title
2002 Intl. EMC Symp.

Keywords

GTEM, OATS, radiated emission, reverberation chamber, anechoic chamber

Citation

Candidi, M. , Holloway, C. , Wilson, P. and Camell, D. (2002), Comparison of Radiated Emission Measurements for 500 MHz to 2 GHz in various EMC Facilities, 2002 Intl. EMC Symp., Sorrento, 1, IT (Accessed April 19, 2024)