Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Calibration of a gamma ray Compton camera for radioactivity measurements

Published

Author(s)

Heather H. Chen-Mayer, Dagistan Sahin, Bryan Remley, Steven Brown, David Goodman

Abstract

A dual-plane Compton imaging detector previously developed for prompt gamma imaging has been further tested and calibrated for quantitative radioactivity determination, specifically to assess radioactive debris from a reactor fuel element containing uranium isotopes and several long-lived fission products, including Cs-137. The detector consists of two pixelated planes of CZT crystals which record gamma ray events interacting within these volumes. In addition to the energy spectrum obtained by pulse height analysis, the time-stamped events from each detector pixel are sorted by location into 3 categories for post-processing: intra-plane, inter-plane, and coincidence. An image reconstruction software enables spatial localization of the select gamma ray peak(s) from the spectrum, thereby separating the gamma ray by specific isotopes. We used the camera to image a small piece of debris for demonstration purposes. A measurement was performed alongside a HPGe detector, which could determine the isotopes' absolute activities and be used as a reference for the camera. In addition, a known isotopic point source was used to calibrate the camera's energy detection efficiency in the same measurement geometry, correlating the image pixel intensity to the isotopic activity.
Citation
Journal of Radioanalytical and Nuclear Chemistry

Keywords

gamma ray imaging, Compton camera, fission product gamma spectrum

Citation

Chen-Mayer, H. , Sahin, D. , Remley, B. , Brown, S. and Goodman, D. (2024), Calibration of a gamma ray Compton camera for radioactivity measurements, Journal of Radioanalytical and Nuclear Chemistry, [online], https://doi.org/10.1007/s10967-024-09729-7, https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=958119 (Accessed October 10, 2024)

Issues

If you have any questions about this publication or are having problems accessing it, please contact reflib@nist.gov.

Created September 10, 2024, Updated September 9, 2024