Assessment of a 12-story Code-Compliant Reinforced Concrete Special Moment Frame Using Performance-Based Seismic Engineering Standards and Guidelines: ASCE 41, TBI, and LATBSDC

Published

Author(s)

Mustafa Buniya, Siamak Sattar, Andre Barbosa

Abstract

A 160-foot tall 12-story reinforced concrete special moment frame building is designed following ASCE 7-10 and ACI 318-14, and assessed using three Performance-Based Seismic Engineering (PBSE) standards and guidelines including ASCE/SEI 41, the Tall Buildings Initiative (TBI) guidelines for performance-based design of tall buildings, and the Los Angeles Tall Buildings Structural Design Council (LATBSDC) procedures. The assessments are performed at the combination of two performance and hazard levels including collapse prevention (CP) at the risk-targeted maximum considered earthquake (MCER) hazard level and immediate occupancy (IO) at a frequent ground motion level with 50 percent probability of exceedance in 30 years, i.e. serviceability performance level. Based on the recommendations of each of the three PBSE documents, nonlinear finite element models are implemented in OpenSees. Through nonlinear time- history response analyses, the finite element models are subjected to eleven ground motions that are selected following the ground motion selection recommendations in ASCE/SEI 7. Assessment results indicate that for the serviceability performance level, the code-compliant building meets the design requirements of the three PBSE documents for the inter-story drift ratio and inelastic deformation of the structural components. At the MCER hazard level, although the building essentially satisfies the design requirements for the peak inter-story drift ratios and inelastic deformation, the mean of the residual inter-story drift ratios as well as the envelope of the residual drift ratios do not meet the limits of the TBI and LATBSDC guidelines. The results indicate that the newly designed building does not meet the design requirements set in TBI and LATBSDC guidelines.
Citation
Aci Structural Journal

Keywords

ASCE/SEI 41, LATBSDC, Nonlinear modeling, Performance-based design, Reinforced concrete, Special moment frame, TBI

Citation

Buniya, M. , Sattar, S. and Barbosa, A. (2020), Assessment of a 12-story Code-Compliant Reinforced Concrete Special Moment Frame Using Performance-Based Seismic Engineering Standards and Guidelines: ASCE 41, TBI, and LATBSDC, Aci Structural Journal, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=923632 (Accessed April 25, 2024)