NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.
Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.
An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
NIST Facility for Spectral Calibration of Detectors: Calibration of Arsenic-Doped Silicon-Blocked Impurity Band Detectors
Published
Author(s)
Adriaan C. Carter, Steven R. Lorentz, Timothy M. Jung, Beverly Klemme, Raju V. Datla
Abstract
The capability of the Low Background Infrared (LBIR) facility at the National Institute of Standards and Technology to spectrally calibrate infrared detectors was demonstrated with the spectral calibration of arsenic doped silicon blocked impurity band (BIB) detectors. The BIB detectors were calibrated over the 2 mm to 30 mm range, using light from a monochromator with a nominal 2 % bandwidth. The calibrations contained less than +/- 1 % standard component of random noise uncertainty, and there was about a +/- 5% standard component of uncertainty arising from systematic effects that will be discussed in detail. The calibrations were performed in ultra-high vacuum in a 20 K background environment by making direct intercomparisons between the power measured by an absolute cryogenic radiometer and the response measured by a detector irradiated by the same beam. A detailed description of measurement methodology and system apparatus is given. Detector linearity and uniformity are also discussed. The LBIR facility can now provide calibrated BIB detectors as transfer standards as well as evaluate and calibrate customers' large area detectors and detector arrays provided the detectors stay within certain physical limitations.
Proceedings Title
Infrared Detectors and Focal Plane Arrays, Conference I 6th | | SPIE
Volume
4028
Conference Dates
April 25-27, 2000
Conference Title
Proceedings of SPIE--the International Society for Optical Engineering
Carter, A.
, Lorentz, S.
, Jung, T.
, Klemme, B.
and Datla, R.
(2000),
NIST Facility for Spectral Calibration of Detectors: Calibration of Arsenic-Doped Silicon-Blocked Impurity Band Detectors, Infrared Detectors and Focal Plane Arrays, Conference I 6th | | SPIE
(Accessed October 8, 2025)