NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.
Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.
An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
Microtensile Bond Strength of Thermally Stressed Composite-Dentin Bonds Mediated by One-Bottle Adhesives
Published
Author(s)
B Xie, Sabine H. Dickens, Anthony A. Giuseppetti
Abstract
Purpose:To evaluate the effects of thermally stressing composite-dentin bonds in teeth subjected to a modified microtensile bond test that allowed application of two bonding agents side-by-side to the same tooth. Materials and Methods: Extracted human molars with a slot dissecting the occlusal dentin surface were conditioned and primed on one side with Prime & Bond NT (PBNT) and Prime One Mirage (P-One) on the other side. The composite was light-cured onto the surface. Approximately 0.5 mm thick dumbbell-shaped tensile specimens were tested after 24-hour water storage or after thermocycling 2400 times at 5 and 55 C. Interfacial morphologies were evaluated by scanning electron microscopy (SEM). Results: Mean tensile bond strengths (TBS standard deviation) were (36 24 Mpa and 31 16 Mpa) for PBNT, and (51 25 Mpa and 40 18 Mpa) for P-One without and with thermocycling, respectively, 97% of all tested specimens failed adhesively. Differences between the bonding systems and the thermal treatments were significant (two-way ANOVA, P< 0.05). Regression analysis showed regional correlation between mean TBS of each bonding agent when grouped by the teeth from which they were obtained (r=0.66, P=0.002). SEM revealed that both bonding agents effectively wetted the conditioned dentin producing a typical hybrid layer, surface-textured resin tags with multiple lateral branches.
Citation
American Journal of Dentistry
Volume
15
Issue
No. 3
Pub Type
Journals
Keywords
dentin bonding, dentin cohesive strength, microtensile bond test, thermocycling
Citation
Xie, B.
, Dickens, S.
and Giuseppetti, A.
(2002),
Microtensile Bond Strength of Thermally Stressed Composite-Dentin Bonds Mediated by One-Bottle Adhesives, American Journal of Dentistry
(Accessed October 14, 2025)