Skip to main content

NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.

Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.

U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Summary of Comparison of Realizations of the ITS-90 Over the Range 83.8058 K to 933.473 K: CCT Key Comparison CCT-K3

Published

Author(s)

Billy W. Mangum, Gregory F. Strouse, William F. Guthrie, R Pello, M F. Stock, E Renaot, Y Hermier, G Bonnier, P Marcarino, K S. Gam, K H. Kang, Y G. Kim, J V. Nicholas, D. R. White, T D. Dransfield, Y Duan, Y Qu, J Connolly, R L. Rusby, J Gray, G J. Sutton, D I. Head, K D. Hill, A G. Steele, K Nara, Tony J. Tegeler, U Noatsch, D Heyer, B Fellmuth, B Thiele-Krivoj, S Duris, A I. Pokhodun, N P. Moiseeva, A G. Ivanova, P A. de Groot, J F. Dubbeldam

Abstract

This is a report to the Comite Consultatif de Thermometrie (CCT) on Key Comparison 3, i.e., the comparison of realizations of the ITS-90 over the range 83.8058 K to 933.473 K. The differences in the realizations of the various fixed points in this range of the ITS-90 and the uncertainties of those differences are given for the 15 standards laboratories participating in the comparison.
Citation
Metrologia
Volume
39
Issue
No. 2

Keywords

fixed-point cells, ITS-90, key comparison, resistance thermometry, SPRT's, temperature, thermometry

Citation

Mangum, B. , Strouse, G. , Guthrie, W. , Pello, R. , Stock, M. , Renaot, E. , Hermier, Y. , Bonnier, G. , Marcarino, P. , Gam, K. , Kang, K. , Kim, Y. , Nicholas, J. , White, D. , Dransfield, T. , Duan, Y. , Qu, Y. , Connolly, J. , Rusby, R. , Gray, J. , Sutton, G. , Head, D. , Hill, K. , Steele, A. , Nara, K. , Tegeler, T. , Noatsch, U. , Heyer, D. , Fellmuth, B. , Thiele-Krivoj, B. , Duris, S. , Pokhodun, A. , Moiseeva, N. , Ivanova, A. , de, P. and Dubbeldam, J. (2002), Summary of Comparison of Realizations of the ITS-90 Over the Range 83.8058 K to 933.473 K: CCT Key Comparison CCT-K3, Metrologia, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=830745 (Accessed October 14, 2025)

Issues

If you have any questions about this publication or are having problems accessing it, please contact [email protected].

Created April 1, 2002, Updated February 17, 2017