Specific Heat Capacity at Constant Volume for Water, Methanol and Their Mixtures at Temperatures From 300 K to 400 K and Pressures to 20 Mpa
Published
Author(s)
T Kuroki, N Kagawa, H. Endo, S Tsuruno, Joe W. Magee
Abstract
Specific heat capacities at constant volume (cv) of water, methanol and their mixtures were measured with a new adiabatic calorimeter experiment. The calorimeter is a twin-cell type whose sample and reference cells (33 cm3) and their shields are heated by electric power. The cells are surrounded by a high vacuum. During the experiment, the heating power was carefully controlled so that the cell temperature increased uniformly. The reference cell was always evacuated and was heated with a constant current. the temperature of the sample cell tracked that of the reference cell temperature by means an automatic control system. Automated sample pressure measurements were made with a crystal quartz transducer. The expanded relative uncertainty for cv is estimated to be 1% for liquid phasw measurements, and for density it is about 0.2%.
Citation
Journal of Chemical and Engineering Data
Volume
46
Issue
5
Pub Type
Journals
Keywords
heat capacity, methanol
Citation
Kuroki, T.
, Kagawa, N.
, Endo, H.
, Tsuruno, S.
and Magee, J.
(2001),
Specific Heat Capacity at Constant Volume for Water, Methanol and Their Mixtures at Temperatures From 300 K to 400 K and Pressures to 20 Mpa, Journal of Chemical and Engineering Data