NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.
Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.
An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
650 GHz bistatic scattering measurements on human skin
Published
Author(s)
Richard A. Chamberlin, Natalie P. Mujica-Schwahn, Erich N. Grossman
Abstract
Many groups are developing submillimeter cameras that will be used to screen human subjects for improvised explosive devices (IEDs) and other threat items hidden beneath their clothing. To interpret submillimeter camera images the scattering properties, specifically the bidirectional scattering distribution function (BSDF) must be known. This problem is not trivial because surfaces of man-made objects and human skin have topographic features comparable to the wavelength of submillimeter radiation-thus simple, theoretical scattering approximations do not apply. To address this problem we built a goniometer instrument to measure the BSDF from skin surfaces of live human subjects illuminated with a beam from a 650 GHz synthesized source. To obtain some multi-spectral information, the instrument was reconfigured with a 160 GHz source. Skin areas sampled are from the hand, interior of the forearm, abdomen, and back. The 650 GHz beam has an approximately Gaussian profile with a FWHM of approximately 1 cm. Instrument characteristics: angular resolution 2.9°; noise floor -45 dB/sr; dynamic range ˃ 70 dB; either s or p-polarization; 25° bidirectional-scattering-angle ≤ 180°; The human scattering target skin area was placed exactly on the goniometer center of rotation with normal angle of incidence to the source beam. Scattering power increased at the higher frequency. This new work enables radiometrically correct models of humans.
Chamberlin, R.
, Mujica-Schwahn, N.
and Grossman, E.
(2014),
650 GHz bistatic scattering measurements on human skin, Proceedings of SPIE: Security + Defense, Baltimore, MD, [online], https://doi.org/10.1117/12.2050729
(Accessed October 14, 2025)