NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.
Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.
An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
NIST traceable measurements of radiance and luminance levels of night-vision-goggle test-instruments
Published
Author(s)
George P. Eppeldauer, Vyacheslav B. Podobedov
Abstract
In order to perform radiance and luminance level measurements of night-vision-goggle (NVG) test instruments, NIST developed new-generation transfer-standard radiometers (TR). The new TRs can perform low-level radiance and luminance measurements with SI traceability and low uncertainty. The TRs were calibrated against NIST detector/radiometer standards holding the NIST photometric and radiometric scales. An 815 nm diode laser was used at NIST for the radiance responsivity calibrations. A spectrally flat (constant) filter correction was made for the TRs to correct the spectral responsivity change of the built-in Si photodiode for LEDs peaking at different wavelengths in the different test sets. The radiance responsivity transfer to the test instruments (test-sets) is discussed. The radiance values of the test instruments were measured with the TRs. The TRs propagate the traceablity to the NIST detector-based reference scales. The radiance uncertainty obtained from three TR measurements was 4.6 % (k=2) at a luminance of 3.43 x 10^-4 cd/m^2. The output radiance of the previously used IR sphere source and the radiance responsivity of a previously used secondary standard detector unit, which was originally calibrated against an IR sphere source, were also measured with the TRs. The performances of the NVG test instruments were evaluated and the manufacturer produced radiance and luminance levels were calibrated with SI/NIST traceability.
Proceedings Title
Proc. 9071, Infrared Imaging Systems: Design, Analysis, Modeling, and Testing XXV Con
Volume
9071
Conference Dates
May 7, 2014
Conference Location
Baltimore, MD
Conference Title
Defense, Security and Sensing Conference of the International Society for Optics and Photonics (SPIE DSS) 2014
Eppeldauer, G.
and Podobedov, V.
(2014),
NIST traceable measurements of radiance and luminance levels of night-vision-goggle test-instruments, Proc. 9071, Infrared Imaging Systems: Design, Analysis, Modeling, and Testing XXV Con, Baltimore, MD, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=916064
(Accessed October 10, 2025)