NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.
Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.
An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
Quantifying CD4 receptor protein in two human CD4+ lymphocyte preparations for quantitative flow cytometry
Published
Author(s)
Meiyao M. Wang, Martin Misakian, Hua-Jun He, Peter Bajcsy, Jeffrey M. Davis, Kenneth D. Cole, Illarion Turko, Lili Wang, Fatima Abbasi
Abstract
For quantitative flow cytometry, a biological cell reference material with a known biomarker expression level is needed to transform a linear arbitrary fluorescence intensity scale obtained with fluorescent microspheres to an antibody bound per cell (ABC) scale. In our previous study of characterizing different human CD4+ lymphocyte preparations, it was found that both commercially available cryopreserved peripheral blood mononuclear cells (PBMC) and a commercially available stabilized and lyophilized PBMC (Cyto-TrolTM) preparation reasonably fulfilled a set of criteria for serving as biological calibrators. However, the biomarker CD4 expression level measured for T helper cells from stabilized cells was about 16% lower than those for cryopreserved PBMC and fresh Whole Blood using both flow cytometry and mass cytometry. A primary reason was hypothesized to be due to steric interference in anti- CD4 antibody binding to the smaller sized stabilized cells. In this study, both multiple reaction monitoring mass spectrometry (MRM-MS) and scanning electron microscopy (SEM) as well as flow cytometry are used to determine likely underlying reasons for the observed difference in the CD4 expression. Because of the stabilization process, a lower CD4 density value, defined as the number of CD4 receptors per CD4+ lymphocyte, from the stabilized cells is most likely explained by the loss of the CD4 receptor proteins suggested by damaged and/or broken microvilli where CD4 receptors reside. Steric hindrance of antibody binding and the association of CD4 receptors with other biomolecules likely contribute significantly to the close to 50% lower CD4 receptor density value for PBMC determined from flow cytometry compared to the value obtained from MRM MS.
Wang, M.
, Misakian, M.
, He, H.
, Bajcsy, P.
, Davis, J.
, Cole, K.
, Turko, I.
, Wang, L.
and Abbasi, F.
(2014),
Quantifying CD4 receptor protein in two human CD4+ lymphocyte preparations for quantitative flow cytometry, Clinical Proteomics, [online], https://doi.org/10.1186/1559-0275-11-43, https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=915357
(Accessed October 15, 2025)