This 2 hour webinar will review and apply Uncertainty Calculations to the Volume Transfer Calibration procedure from the "SOP 19 (18) Part 1" webinar.  
Learning Objectives:
 When this webinar is completed, participants will be able to:  
- IDENTIFY the components of uncertainty for the SOP 18 process and use them to develop an uncertainty budget 
 - QUANTIFY the components of uncertainty for the SOP 18 process 
 - CALCULATE the uncertainty of your SOP 18 process    
 
Technology Requirement(s): 
The Webcast will be streamed in medium bandwidth (350kbs), so viewers needed to have a constant connection during the webcast.    
- Hardware and operating system configurations:
 
- Windows XP (Explorer 8, 9, 10, 11; Mozilla Firefox; Google Chrome) 
 - Windows Vista (Internet Explorer or Firefox) 
 - Windows 7 or 8 (Mozilla Firefox; Google Chrome) 
 - Apple Mac OS 10.5x (Mozilla Firefox; Apple Safari; Google Chrome) 
 - Ubuntu Linux (Firefox only)   
 
Media players In order to access the event, you must have, at a minimum, Adobe® Flash® Player 11.2+ installed on your computer. Please visit http://get2.adobe.com/flashplayer/ to download the Flash Player.   Internet browsers In order to access the event, you must have either Microsoft Internet Explorer (Explorer 8, 9, 10, 11) or Mozilla Firefox 3+ browser for Windows operating systems. For accessing events via Mac operating systems you must have Mozilla Firefox 3+ or Safari 4.x.  Optional: If you have never attended an Adobe Connect meeting before: Test your connection: http://nist.adobeconnect.com/common/help/en/support/meeting_test.htm  Get a quick overview: http://www.adobe.com/products/adobeconnect.html   Materials & Supplies:
None.  
Prerequisite(s):
Participants must have successfully completed NISTIR 7383 SOP 18 Part 1.  
Pre-Work:
- To prepare for this webinar, participation in the April 8 webinar "NISTIR 7383 SOP 19 (18) - Part 1" is required.   
 - Look over SOPs 18, 19 and 29 one more time. 
 - Be prepared to discuss the sources of error and your uncertainty budget for your 5 gallon test measure calibration during the webinar.  
 
Pre-work Deadline:
Complete calibration of a 5 gallon test measure, using either SOP 18 or 19, submitting the calibration report to Val Miller by e-mail or fax (e-mail: val.miller [at] nist.gov (val[dot]miller[at]nist[dot]gov), fax 301-975-8091) by 10 AM Eastern Time Zone on April 9.
Minimum Requirement(s):
Completion includes completing pre-work assignment, full attendance and participation in the session activities and discussion.
Audience:
Laboratory personnel who have responsibilities for developing, implementing, and/or improving the quality management system in their laboratory as well as those who are seeking OWM recognition and/or accreditation or improvements to support recognition/accreditation.  This course is available for weights and measures participants only. 
Cost:
Registration fees for State weights and measures regulatory officials and metrologists are funded by NIST OWM.
Instructor(s):
 Val Miller
Office of Weights and Measures
Phone: (301) 975 - 3602
Email: val.miller [at] nist.gov (val[dot]miller[at]nist[dot]gov)