Skip to main content

NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.

Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.

U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Pushing the Limits of Bottom-Up Gold Filling for X-Ray Grating Interferometry

Published

Author(s)

Daniel Josell, Thomas Moffat, Z Shi, K Jefimovs, L Romano, J. Vila-Comamala

Abstract

The application of superconformal Bi-catalyzed Au electrodeposition for void-free filling of recessed trenches in X-ray gratings used in phase contrast imaging is detailed. Filling of trenches with aspect ratio (height divided by its width) up to 55 is demonstrated. Uniform bottom-up filling of patterned trench arrays across a 4 inch (10 cm) diameter Si wafer is accomplished using a well defined hydrodynamic flow field across the wafer surface. The filling process and microstructure are examined by scanning electron microscopy of cross-sectioned specimens. The importance of process optimization, from the design of potential (current) programming to electrolyte pH and concentrations of Na3Au(SO3)2 and Bi3+, for the filling of high aspect ratio trenches is demonstrated. X-ray phase contrast imaging is used to assay the quality and uniformity of the as-formed gratings as well as demonstrate their application to imaging biological tissue. Successful void-free Au filling of micrometer pitch, high aspect ratio trenches in Si gratings promises to advance X-ray grating interferometry and its application to X-ray phase contrast imaging.
Citation
Journal of the Electrochemical Society
Volume
167

Keywords

grating, medical imaging, imaging, gold, superconformal, superfill, trenches

Citation

Josell, D. , Moffat, T. , Shi, Z. , Jefimovs, K. , Romano, L. and Vila-Comamala, J. (2020), Pushing the Limits of Bottom-Up Gold Filling for X-Ray Grating Interferometry, Journal of the Electrochemical Society, [online], https://doi.org/10.1149/1945-7111/ abba63, https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=930899 (Accessed October 1, 2025)

Issues

If you have any questions about this publication or are having problems accessing it, please contact [email protected].

Created September 30, 2020, Updated September 29, 2025
Was this page helpful?