| Name | Test100_RadPlank_R3
|
|---|---|
| Date | |
| Description | Pine board 2x10x96 Ignition=Radiant Panel w/ 2 in separation from short end face |
| Specimen | wood plank
|
| Ignition | radiant panel
|
| Project ID (s) | |
| Test Director | McGrattan
|
| Measurement | Value | Uc | Unit |
|---|---|---|---|
| Peak Heat Release Rate, PHRR
|
0.89
|
0.47
|
kW
|
| Time to Peak Heat Release Rate
|
13.10
|
0.17
|
min
|
| Total Heat Released, THR
|
below detection limit
|
0.31
|
MJ
|
| Gas Burner Total Heat Released, NGTHR
|
0
|
- | MJ
|
| Heat Release Quality Confirmation, HRQC
|
Not measured | - | MJ/MJ
|
| Net Specimen Mass (gravimetric), NM = Mi-Mf
|
0.116
|
0.028
|
kg
|
| Net Effective Heat of Combustion = THR / NM
|
below detection limit
|
2.8
|
MJ/kg
|
| O2 Yield = O2 Consumed / NM
|
below detection limit
|
0.23
|
kg/kg
|
| CO2 Yield = CO2 Generated / NM
|
0.188
|
0.082
|
kg/kg
|
| CO Yield = CO Generated / NM
|
0.099
|
0.031
|
kg/kg
|
| Soot Yield = Soot Generated / NM
|
0.0110
|
0.0073
|
kg/kg
|
| Baseline Hood Exhaust Flow
|
2.138
|
0.064
|
kg/s
|
| Test Duration = Time(Fire Out) - Time(Ignition)
|
20.32
|
0.03
|
min
|
Uc = Combined Expanded Uncertainty with 95% confidence level
| Parameter | Value | Uc | Unit |
|---|---|---|---|
| Fuel Type
|
Cellulose
|
- | - |
| Hood Size
|
3
|
- | m
|
| Effective Duct Diameter
|
0.485
|
0.005
|
m
|
| Exhaust Flow Correction Factor
|
1.033
|
0.029
|
- |
| Net Heat of Combustion (per unit mass O2), Ef
|
13.61
|
0.41
|
MJ/kg
|
| Net Heat of Combustion(per unit mass fuel), HOCf
|
16.12
|
0.60
|
MJ/kg
|
| Initial Specimen Mass, Mi (gravimetric)
|
below detection limit
|
0.02
|
kg
|
| Final Specimen Mass, Mf (gravimetric)
|
below detection limit
|
0.02
|
kg
|
| Event | Time (min) | Description | Video Snapshot Image |
|---|---|---|---|
| 1
|
-5.62
|
radiant panel ON
|
|
| 2
|
0.00
|
Ignition
|
|
| peak
|
13.10
|
Peak HRR
|
|
| 3
|
20.03
|
radiant panel OFF
|
|
| 4
|
20.32
|
Fire Out
|
|
Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019
https://doi.org/10.6028/NIST.TN.2077
NIST Fire Calorimetry Database (FCD)
https://doi.org/10.18434/mds2-2314