NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.
Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.
An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
High-resolution neutron depolarization microscopy of the ferromagnetic transitions inNi3Al and HgCr2Se4 under pressure
Published
Author(s)
Daniel S. Hussey, Muhammad Abir, B. Khaykovich, C. Pfleiderer, Pau Jorba, Marc Seifert, Michael Schulz
Abstract
We performed spatially resolved imaging of ferromagnetic transitions in Ni3Al and HgCr2Se4 crystals. These neutron depolarization measurements discovered bulk magnetic inhomogeneities in the ferromagnetic transition temperature with the spatial resolution about 100 m. To obtain such spatial resolution, we employed a novel neutron microscope equipped with Wolter mirrors as a neutron image-forming lens and a focusing neutron guide as a neutron condenser lens. The images of Ni3Al show that the sample does not homogeneously go through the ferromagnetic transition. The improved resolution allowed us to identify a distribution of small grains with slightly o -stoichiometric composition. Additionally, neutron depolarization imaging experiments on the chrome spinel, HgCr2Se4, under high pressures up to 15 kbar highlight the advantages of the new technique especially for small samples or sample environments with restricted sample space. The improved spatial resolution enables to observe domain formation in the sample while decreasing the acquisition time despite having a bulky pressure cell in the beam. The novel optical design that enabled acquisition of the high spatial resolution neutron depolarization images is described in detail and image results are compared to a conventional radiography setup without a lens.
, D.
, Abir, M.
, Khaykovich, B.
, Pfleiderer, C.
, Jorba, P.
, Seifert, M.
and Schulz, M.
(2021),
High-resolution neutron depolarization microscopy of the ferromagnetic transitions inNi3Al and HgCr2Se4 under pressure, Physical Review B, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=925285
(Accessed October 9, 2025)