NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.
Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.
An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
A system for probing Casimir energy corrections to the condensation energy
Published
Author(s)
Diego J. Perez, Alexander Stange, Richard Lally, Lawrence Barrett, Matthias Imboden, Abhishek Som, David Campbell, Vladimir Aksyuk, David Bishop
Abstract
In this article, we present a nano-electromechanical system (NEMS) designed to detect changes in the Casimir Energy. The Casimir effect is a result of the appearance of quantum fluctuations in the electromagnetic vacuum. Previous experiments have used nano- or micro-scale parallel plate capacitors to detect the Casimir force by measuring the small attractive force these fluctuations exert between the two surfaces. In this new set of experiments, we aim to directly detect shifts in the Casimir energy in the vacuum due to the presence of metallic parallel plates, one of which is a superconductor. A change in the Casimir energy of this configuration is predicted to shift the superconducting transition temperature (Tc) because of an interaction between it and the superconducting condensation energy. The experiment we discuss consists of taking a superconducting film, carefully measuring its transition temperature, bringing a conducting plate close to the film, creating a Casimir cavity, and then measuring the transition temperature again. The expected shifts will be small, comparable to the normal shifts one sees in cycling superconducting films to cryogenic temperatures and so using a NEMS resonator and doing this in-situ is the only practical way to obtain accurate, reproducible data. Using a thin Pb film and opposing Au surface, we observe no shift in Tc greater than 12 µK down to a minimum spacing of approximately 70 nm.
Perez, D.
, Stange, A.
, Lally, R.
, Barrett, L.
, Imboden, M.
, Som, A.
, Campbell, D.
, Aksyuk, V.
and Bishop, D.
(2020),
A system for probing Casimir energy corrections to the condensation energy, Microsystems & Nanoengineering, [online], https://doi.org/10.1038/s41378-020-00221-2, https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=930132
(Accessed October 11, 2025)