Fire Calorimetry Data

Fire Safety Challenges of Tall Wood Buildings – Phase 2: Task 3 - Cross Laminated Timber Compartment Fire Tests Project

Hoehler, M. Dataset from Fire Safety Challenges of Tall Wood Buildings - Phase 2: Task 3 - Cross Laminated Timber Compartment Fire Tests, 2017 https://doi.org/10.18434/T4/1422512

Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019 https://doi.org/10.6028/NIST.TN.207

 

Experiment Name Date/Time Project ID Project PI Specimen Fuel Type Ignition Test Duration (min) Total Heat Released (MJ) Peak HRR (kW)
CLT Room Test 1-1 2/16/2017 10:10:49 AM NRCC_CLT M. Hoehler, J. Su furnished studio apartment Cellulose, Plastics natural gas burner 135 18634.1 9886
CLT Room Test 1-2 2/23/2017 9:49:34 AM NRCC_CLT M. Hoehler, J. Su furnished studio apartment Cellulose, Plastics natural gas burner 108 19319.3 12974
CLT Room Test 1-3 3/16/2017 10:19:16 AM NRCC_CLT M. Hoehler, J. Su furnished studio apartment, CLT wall Cellulose, Plastics natural gas burner 247 33811.2 14766
CLT Room Test 1-4 3/21/2017 9:51:10 AM NRCC_CLT M. Hoehler, J. Su furnished studio apartment, CLT ceiling Cellulose, Plastics natural gas burner 176 37450.5 13665
CLT Room Test 1-5 4/13/2017 9:49:48 AM NRCC_CLT M. Hoehler, J. Su furnished studio apartment, CLT wall Cellulose, Plastics natural gas burner 220 55830.6 10808
CLT Room Test 1-6 4/18/2017 9:51:29 AM NRCC_CLT M. Hoehler, J. Su furnished studio apartment, CLT wall and ceiling Cellulose, Plastics natural gas burner 193 81484.4 13452
Created December 6, 2019, Updated February 27, 2020