Experimental Study on Long-Span Composite Floor Beams Subject to Fire: Baseline Data at Ambient Temperature

Published

Author(s)

Lisa Y. Choe, Selvarajah Ramesh, Matthew S. Hoehler, John L. Gross

Abstract

The National Institute of Standards and Technology recently expanded its large-scale structural-fire testing capabilities in the National Fire Research Laboratory. A landmark test series is being conducted on long-span steel-concrete composite floor beams designed and constructed following U.S. building codes and standards. The test program consists of five 13 m span composite beams with one of two types of shear connections: bolted/welded double-angle connections or single plate shear connections. Two of the five specimens have slab continuity at the beam ends. This paper presents the results from a recent test on the composite beam conducted at ambient temperature. The experimentally measured behavior and flexural moment capacity will be used as a baseline to compare with the composite beams still to be tested under combined mechanical and fire load. The datasets produced are providing technical information necessary to advance performance-based design of composite floor systems in steel- framed buildings subject to fire.
Proceedings Title
Structures Congress 2018
Conference Dates
April 19-21, 2018
Conference Location
Fort Worth, TX

Keywords

steel-concrete composite beams, steel connections, structural-fire experiments

Citation

Choe, L. , Ramesh, S. , Hoehler, M. and Gross, J. (2018), Experimental Study on Long-Span Composite Floor Beams Subject to Fire: Baseline Data at Ambient Temperature, Structures Congress 2018, Fort Worth, TX, [online], https://doi.org/10.1061/9780784481325.015 (Accessed October 2, 2025)

Issues

If you have any questions about this publication or are having problems accessing it, please contact [email protected].

Created April 17, 2018, Updated November 10, 2018
Was this page helpful?