| Name | e12_LiPoly_3_PU_FC
|
|---|---|
| Date | |
| Description | puncture test burnout setup. Lithium polymer (3-B) battery fully charged. |
| Specimen | LiPoly Battery
|
| Ignition | puncturing
|
| Project ID (s) | |
| Test Director | Falkenstein
|
| Measurement | Value | Uc | Unit |
|---|---|---|---|
| Peak Heat Release Rate, PHRR
|
4.8
|
1.5
|
kW
|
| Time to Peak Heat Release Rate
|
0.67
|
0.07
|
min
|
| Total Heat Released, THR
|
below detection limit
|
0.15
|
MJ
|
| Gas Burner Total Heat Released, NGTHR
|
0.6287
|
0.0090
|
MJ
|
| Heat Release Quality Confirmation, HRQC
|
Not measured | - | MJ/MJ
|
| Net Specimen Mass (gravimetric), NM = Mi-Mf
|
Not measured | - | kg
|
| Total Fuel Mass Burned, TFM = THR / HOCf
|
below detection limit
|
0.017
|
kg
|
| Net Effective Heat of Combustion = THR / NM
|
Not measured | - | MJ/kg
|
| O2 Yield = O2 Consumed / TFM
|
-1.0
|
-1.9
|
kg/kg
|
| CO2 Yield = CO2 Generated / TFM
|
0.0
|
-1.0
|
kg/kg
|
| CO Yield = CO Generated / TFM
|
below detection limit
|
0.33
|
kg/kg
|
| Soot Yield = Soot Generated / TFM
|
below detection limit
|
0.57
|
kg/kg
|
| Baseline Hood Exhaust Flow
|
2.137
|
0.064
|
kg/s
|
| Test Duration = Time(End of Test) - Time(Start of Test)
|
8.72
|
0.03
|
min
|
Uc = Combined Expanded Uncertainty with 95% confidence level
| Parameter | Value | Uc | Unit |
|---|---|---|---|
| Fuel Type
|
Generic
|
- | - |
| Hood Size
|
3
|
- | m
|
| Effective Duct Diameter
|
0.483
|
0.004
|
m
|
| Exhaust Flow Correction Factor
|
1.033
|
0.029
|
- |
| Net Heat of Combustion (per unit mass O2), Ef
|
13.10
|
2.62
|
MJ/kg
|
| Net Heat of Combustion(per unit mass fuel), HOCf
|
10.00
|
6.00
|
MJ/kg
|
| Initial Specimen Mass, Mi (gravimetric)
|
Not measured | - | kg
|
| Final Specimen Mass, Mf (gravimetric)
|
Not measured | - | kg
|
| Event | Time (min) | Description | Video Snapshot Image |
|---|---|---|---|
| 1
|
0.00
|
Start of Test
|
|
| 2
|
0.52
|
battery puncture
|
|
| peak
|
0.67
|
Peak HRR
|
|
| 3
|
8.05
|
stop filter sampling
|
|
| 4
|
8.72
|
End of Test
|
|
| 5
|
8.72
|
fuel ON
|
|
| 6
|
8.78
|
torch ignition
|
|
| 7
|
21.00
|
Fuel OFF
|
|
| 8
|
21.12
|
Fire Out
|
|
Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019
https://doi.org/10.6028/NIST.TN.2077
NIST Fire Calorimetry Database (FCD)
https://doi.org/10.18434/mds2-2314