Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

1B-WCl0-0

Table 1. Test Information
Name
1B-WCl0-0
Date
Description

Wood Closet against target wall. Specimen: wood closet (49.56 kg) low fuel load: wood cribs (2 x 1A) (39.9 kg) 300mL Heptane

Specimen
Wood Shed Wood Cribs
Ignition
heptane pan
Project ID (s)
Test Director
Maranghides A

Timelapse Video with Heat Release Rate Plot

Table 2. Summary of Test Results
Measurement Value Uc Unit
Peak Heat Release Rate, PHRR
3,381
172
kW
Time to Peak Heat Release Rate
5.47
0.17
min
Total Heat Released, THR
688
36
MJ
Natural Gas Burner Total Heat Released, NGTHR
-1
-
MJ
Heat Release Quality Confirmation, HRQC
Not measured -
MJ/MJ
Net Specimen Mass (gravimetric), NM = Mi-Mf
Not measured -
kg
Total Fuel Mass Burned, TFM = THR / HOCf
42.6
2.6
kg
Net Effective Heat of Combustion = THR / NM
Not measured -
MJ/kg
O2 Yield = O2 Consumed / TFM
1.245
0.085
kg/kg
CO2 Yield = CO2 Generated / TFM
1.61
0.11
kg/kg
CO Yield = CO Generated / TFM
0.0255
0.0018
kg/kg
Soot Yield = Soot Generated / TFM
0.00533
0.00098
kg/kg
Baseline Hood Exhaust Flow
24.32
0.73
kg/s
Test Duration = Time(Fire Out) - Time(Ignition)
12.48
0.03
min

Uc = Combined Expanded Uncertainty with 95% confidence level

Table 3. Summary of Test Input Parameters
Parameter Value Uc Unit
Fuel Type
Cellulose
- -
Hood Size
9
-
m
Effective Duct Diameter
1.975
0.005
m
Exhaust Flow Correction Factor
1.055
0.034
-
Net Heat of Combustion (per unit mass O2), Ef
13.10
0.52
MJ/kg
Net Heat of Combustion(per unit mass fuel), HOCf
16.12
0.50
MJ/kg
Initial Specimen Mass, Mi (gravimetric)
89.42
0.02
kg
Final Specimen Mass, Mf (gravimetric)
Not measured -
kg
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Figure 1. Plot of Heat Release Rate data with event markers and error bars shown at peak.
Table 4. Summary of Observed Test Events
Event Time (min) Description Video Snapshot Image
1
0.00
Ignition
Ignition
peak
5.47
Peak HRR
Peak HRR
2
6.03
Target wall window break
Target wall window  break
3
6.52
roof ignition front
roof ignition front
4
7.63
shed suppression
shed suppression
5
8.00
suppress front of roof
suppress front of roof
6
10.03
suppress back of roof
suppress back of roof
7
12.48
Fire Out
Fire Out

Table 5. Supplemental Data Plots

Plot of Oxygen Dry Volume Fraction in hood exhaust stream.
Plot of Oxygen Dry Volume Fraction in hood exhaust stream.
Plot of Carbon Dioxide Dry Volume Fraction in hood exhaust stream.
Plot of Carbon Dioxide Dry Volume Fraction in hood exhaust stream.
Plot of Carbon Monoxide Dry Volume Fraction in hood exhaust stream.
Plot of Carbon Monoxide Dry Volume Fraction in hood exhaust stream.
Plot of Radiant Heat Flux data with event markers. r= radial distance from center of hood, h=height above floor.
Plot of Radiant Heat Flux data with event markers. r= radial distance from center of hood, h=height above floor.
Plot of Smoke Laser Extinction Coefficient in hood exhaust stream.
Plot of Smoke Laser Extinction Coefficient in hood exhaust stream.
Plot of Exhaust Duct Mass Flow Rate.
Plot of Exhaust Duct Mass Flow Rate.

Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019
https://doi.org/10.6028/NIST.TN.2077

NIST Fire Calorimetry Database (FCD)
https://doi.org/10.18434/mds2-2314

Report Process Script Version
NFRL_Report_8.4.6
Last Updated September 22, 2022