Experiment Name Plot of Heat Release Rate Ignition Photo Date/Time Project Specimen Fuel Type Sort descending Total Heat Released (MJ) Peak HRR (kW)
Test51_ABS_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels 1/4" thick, 24" wide, 96" tall panels of ABS Acrylonitrile Butadiene Styrene (ABS)
566
3,538
Test47_ABS_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels 1/4" thick, 24" wide, 96" tall panels of ABS Acrylonitrile Butadiene Styrene (ABS)
547
3,821
Test53_ABS_R3
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Vertical Upward Flamespread on Parallel Panels 1/4" thick, 24" wide, 96" tall panels of ABS Acrylonitrile Butadiene Styrene (ABS)
550
3,541
Test15_4woodCrib_r1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Multiple Item Transient Combustion Calorimetry wood cribs Cellulose
2,523
1,402
1B-SVSh0-5
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Structure Separation Experiments: Shed Burns without Wind Steel Shed Wood Cribs Cellulose
780
2,711
Test012_BigBoxPaper 2ft_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) cardboard and shreded paper Cellulose
36.1
482
Test16_8woodCrib_r1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Multiple Item Transient Combustion Calorimetry wood cribs Cellulose
5,120
2,301
1B-SVSh0-5_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Structure Separation Experiments: Shed Burns without Wind Steel Shed Wood Cribs Cellulose
956
3,123
Test093_Pallet_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) pallet Cellulose
0.71
2.11
Test32_box_r2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Multiple Item Transient Combustion Calorimetry cardboard boxes filled with paper Cellulose
103.6
132.6
Test1_1box_r1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Multiple Item Transient Combustion Calorimetry cardboard boxes filled with paper Cellulose
116.3
328
Test014_BigEmptyBox2ft_R3
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) empty cardboard box Cellulose
26.5
443
1B-WC00-0
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Structure Separation Experiments: Shed Burns without Wind Wood Shed Cellulose
772
2,784
Test094_Pallet_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) pallet Cellulose
1.16
2.58
Test33_2box_r2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Multiple Item Transient Combustion Calorimetry cardboard boxes filled with paper Cellulose
223
267
Test2_2box_r1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Multiple Item Transient Combustion Calorimetry cardboard boxes filled with paper Cellulose
236
481
Test095_RadPallet_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
rad panel ON
Transient Combustion Calorimetry (TCC) pallet Cellulose
below detection limit
0.89
Test34_4box_r2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Multiple Item Transient Combustion Calorimetry cardboard boxes filled with paper Cellulose
442
288
Test3_4box_r1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Multiple Item Transient Combustion Calorimetry cardboard boxes filled with paper Cellulose
479
944
1B-WCh0
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Structure Separation Experiments: Shed Burns without Wind Wood Shed Wood Cribs Cellulose
2,110
4,171

Bryant, R. and Bundy, M. The NIST 20 MW Calorimetry Measurement System for Large-Fire Research, Technical Note (NIST TN) 2077, 2019
https://doi.org/10.6028/NIST.TN.2077

NIST Fire Calorimetry Database (FCD)
https://doi.org/10.18434/mds2-2314