Test061_250mL_propanol_R3
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) propanol liquid Plastic
7.17
147.4
Test012_BigBoxPaper 2ft_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) cardboard and shreded paper Cellulose
36.1
482
Test077_PlasticChain_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) Plastic chain Plastic
32.1
30.1
Test030_GardenHose_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) Rubber hose Rubber
41.8
24.9
Test094_Pallet_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) pallet Cellulose
1.16
2.58
Test046_ShopVac_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) Plastic shop vaccum Plastic
295
545
NGCal_3mHood_300kW_2kgs
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) box gas burner Natural Gas
186.9
328
Test062_250mL_Linseed_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) linseed oil Plastic
1.15
1.92
Test014_BigEmptyBox2ft_R3
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) empty cardboard box Cellulose
26.5
443
Test078_PlasticChain_R3
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) Plastic chain Plastic
26.2
21.3
Test079_NylonRope_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) Nylon rope Nylon
92.0
76.0
Test031_ExtensionCord12awg_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) electric cord Plastic
below detection limit
1.02
Test095_RadPallet_R1
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
rad panel ON
Transient Combustion Calorimetry (TCC) pallet Cellulose
below detection limit
0.89
Test047_ShopVac_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) Plastic shop vaccum Plastic
below detection limit
1.92
Test063_250mL_Linseed_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) linseed oil Plastic
1.00
1.75
Test015_BigBoxPeanuts2ft_R3
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) cardboard and expanded polystyrene (EPS) peanuts Cellulose, Plastic
38.0
595
Test016_BigBoxShreds2ft_R3
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) cardboard and shreded paper Cellulose
36.1
369
Test080_NylonRope_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) Nylon rope Nylon
0.261
3.01
Test032_ExtensionCord12awg_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
Ignition
Transient Combustion Calorimetry (TCC) electric cord Plastic
below detection limit
below detection limit
Test096_RadPallet_R2
Plot of Fire Heat Release Rate with event markers. Uncertainty bar shown at peak value.
radiant panel ON (warm up)
Transient Combustion Calorimetry (TCC) pallet Cellulose
below detection limit
below detection limit