Skip to main content

NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.

Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.

U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Thermal Conductivity of Liquid trans-1,2-Dichloroethene (R-1130(E)): Measurement and Modeling

Published

Author(s)

Karim Al-Barghouti, Aaron Rowane, Ian Bell, Marcia L. Huber, Richard A. Perkins

Abstract

The thermal conductivity of liquid trans-1,2-dichloroethene (R-1130(E)) was measured at temperatures ranging from 240 K to 340 K and pressures up to 25 MPa using a transient hot-wire instrument. A total of 447 thermal conductivity data points were measured along six isotherms. Each isotherm includes data at nine pressures, which were chosen to be at equal density increments starting at a pressure of 0.1 MPa (or slightly above the saturation pressure of R-1130(E) at temperatures above its normal boiling point) to a maximum pressure of 25 MPa. The combined expanded uncertainty of the presented experimental data is 1.4% at a 95% confidence level. The experimental data were used to evaluate the performance of an extended corresponding states (ECS) model and a residual entropy scaling (RES) model. Both models were applied in a totally predictive mode, and in a mode where the experimental data were used to tune the model parameters. A volume-translated Peng–Robinson equation of state was used to provide thermodynamic properties needed to apply both models. In a totally predictive mode, the ECS model had an average absolute relative deviation (ΔAARD) of 6.89% relative to the experimental data with the largest deviation being − 8.33%. The RES model in a totally predictive mode showed an ΔAARD of 2.55% with the largest deviation being − 5.81%. When model parameters were fitted to the experimental data, both the ECS and the RES model represented the experimental data to within its uncertainty of 1.4%.
Citation
International Journal of Thermophysics

Keywords

Extended Corresponding States, Thermal Conductivity, R-1130(E), trans-1, 2-dichloroethene, Transient Hot-Wire, Low GWP, Residual Entropy Scaling

Citation

Al-Barghouti, K. , Rowane, A. , Bell, I. , Huber, M. and Perkins, R. (2024), Thermal Conductivity of Liquid trans-1,2-Dichloroethene (R-1130(E)): Measurement and Modeling, International Journal of Thermophysics, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=956920 (Accessed October 9, 2025)

Issues

If you have any questions about this publication or are having problems accessing it, please contact [email protected].

Created February 12, 2024, Updated September 9, 2024
Was this page helpful?