Skip to main content
U.S. flag

An official website of the United States government

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Secure .gov websites use HTTPS
A lock ( ) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Recent Experiments Assessing the Uncertainty of Metal Cutting Temperature Measurements When Using the NIST High Speed Dual Spectrum Optical System

Published

Author(s)

Eric P. Whitenton, April L. Cooke, Jarred Heigel, Ivan Arriola Aldamiz

Abstract

Process models, including finite element modeling simulations, are important for optimizing the metal cutting process, allowing industry to make parts faster, better, and at less cost. Measurements of the process can be used to improve and verify the accuracy of these models. There are many error sources when using infrared radiation thermography to measure the temperature distribution of the tool, workpiece, and chip during metal cutting. Furthermore, metal cutting presents unique measurement challenges due to factors such as the high magnification required, high surface speeds, micro-blackbody effects, and changing emissivity as chips form. As part of an ongoing effort to improve our understanding of uncertainties associated with these thermographic measurements, two sets of experiments were performed. One set explored how well the surface temperature of the cutting tool accurately reflects the internal temperature. This was accomplished by simultaneously measuring the temperature using both a thermal camera and a thermocouple embedded within the cutting tool. The other set investigated correcting for motion blur, point spread function, and a less than ideal range of sensitivity of the thermal camera when measuring the shear zone temperature of the chip. In theory, this correction could be performed using deconvolution. Unfortunately, deconvolutions are sensitive to noise and it is difficult to gauge the uncertainty of the computed values. Thus, convolutions of various assumed inputs were computed and compared to the measured temperatures. Assumed inputs which yielded a good fit to the measured temperatures were considered candidate values. The range of those candidate values yields a measure of the uncertainty of the calculation.
Proceedings Title
Proceedings of SPIE, ThermoSense XXXII
Volume
7661
Conference Dates
April 5-9, 2010
Conference Location
Orlando, FL
Conference Title
Part of SPIE Defense, Security and Sensing Conference

Keywords

uncertainty, metal cutting, dual-spectrum, high-speed imaging, infrared thermography

Citation

Whitenton, E. , Cooke, A. , Heigel, J. and Arriola, I. (2010), Recent Experiments Assessing the Uncertainty of Metal Cutting Temperature Measurements When Using the NIST High Speed Dual Spectrum Optical System, Proceedings of SPIE, ThermoSense XXXII, Orlando, FL, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=904866 (Accessed October 3, 2024)

Issues

If you have any questions about this publication or are having problems accessing it, please contact reflib@nist.gov.

Created May 11, 2010, Updated February 19, 2017