NOTICE: Due to a lapse in annual appropriations, most of this website is not being updated. Learn more.
Form submissions will still be accepted but will not receive responses at this time. Sections of this site for programs using non-appropriated funds (such as NVLAP) or those that are excepted from the shutdown (such as CHIPS and NVD) will continue to be updated.
An official website of the United States government
Here’s how you know
Official websites use .gov
A .gov website belongs to an official government organization in the United States.
Secure .gov websites use HTTPS
A lock (
) or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.
Realization and Application of a Detector-Based Tristimulus Color Scale at the National Institute of Standards and Technology, USA
Published
Author(s)
George P. Eppeldauer, Steven W. Brown, Keith R. Lykke, Yoshihiro Ohno
Abstract
The recently introduced detector-based calibration method for tristimulus colorimeters has been realized. The NIST reference colorimeter has been calibrated for spectral irradiance responsivity with an uncertainty of 0.15 % (coverage factor k=2) resulting in a chromaticity uncertainty of 0.0004 (k=2) in the x and y chromaticity coordinates when a CIE Illuminant A source is measured. The color scale is realized and maintained by reference colorimeters rather than reference lamps. The color measurement uncertainty increases when sources other than Illuminant A are measured due to spectral mismatch errors of the channels. Variable reference source models have been developed so that the reference source for the colorimeter can be automatically matched to the measured test source of certain types. A model using Planckian radiation with a variable temperature has been tested and proved to be effective in eliminating the mismatch errors for incandescent lamps. Another model based on primary colors of a display has also been tested and proved to be effective.
Proceedings Title
AIC | 10th| Congress of the International Colour Association | AIC
calibration, chromaticity, color measurement, color scale, color standard, colorimetry, spectral responsivity, tristimulus colorimeter
Citation
Eppeldauer, G.
, Brown, S.
, Lykke, K.
and Ohno, Y.
(2005),
Realization and Application of a Detector-Based Tristimulus Color Scale at the National Institute of Standards and Technology, USA, AIC | 10th| Congress of the International Colour Association | AIC, Granada, SP, [online], https://tsapps.nist.gov/publication/get_pdf.cfm?pub_id=840951
(Accessed October 11, 2025)