Performance Evaluation of a Reciprocating Chiller Using Experimental Data and Model Predictions for Fault Detection and Diagnosis

Published

Author(s)

Natascha S. Milesi-Ferretti

Abstract

tecting degradation faults remains a challenge in spite of the advances in monitoring and controls software. Basic monitoring equipment can be used to detect the most obvious faults. However, degradation faults can have a small effect on the system s ability to control building conditions and occupant s comfort while having a large effect on energy consumption and expected equipment life. Research conducted over the past decade has sought to enable a building energy management system (BEMS) with embedded fault detection and diagnostic software to identify typical system faults, generating warning alarms if the system performance begins to degrade.This paper presents a model-based approach to fault detection and diagnostics for a reciprocating chiller and examines the performance of the method using simulation and experimental data. MATCH (model-based assessment tool for chillers), the implementation of the classifier and expert rule set in the software, was first applied to fault-free and faulty experimental data using seven performance indices. As expected, the ability to detect faults is influenced by the severity of the fault and the operating conditions. MATCH successfully detected and diagnosed condenser fouling, refrigerant undercharge, and refrigerant overcharge at an fault level of 20% or greater and evaporator fouling and liquid line restriction at a fault level of 30% or greater. Results highlight the difficulty of detecting and diagnosing a liquid line restriction for systems using thermal expansion devices.
Volume
108
Issue
Pt. 1
Conference Dates
January 13-16, 2002
Conference Title
ASHRAE Transactions

Keywords

chiller, condenser, diagnostics, efficiency, fault detection, reciprocating compressor

Citation

Milesi-Ferretti, N. (2002), Performance Evaluation of a Reciprocating Chiller Using Experimental Data and Model Predictions for Fault Detection and Diagnosis, ASHRAE Transactions (Accessed October 9, 2024)

Issues

If you have any questions about this publication or are having problems accessing it, please contact reflib@nist.gov.

Created January 1, 2002, Updated February 19, 2017