PERFORMANCE CRITERIA FOR CHEMICAL ANALYSIS OF HYDRAULIC CEMENTS BY X-RAY FLOURESCENCE ANALYSIS

Published

Author(s)

Paul E. Stutzman

Abstract

Bulk oxide determinations from two pairs of ASTM C150 portland cements are used to calculate precision and accuracy values for X-ray fluorescence (XRF) by both the fused glass bead and the pressed powder sample preparation methods. The first pair of cements are ordinary portland cement (OPC) with 45 participants while the second pair contains ca. 3 % limestone, with 24 labs participating. Each lab provided results from six replicates analyzed in duplicate, covering fifteen analytes, CaO, SiO2, Al2O3, Fe2O3, SO3, MgO, Na2O, K2O, TiO2, P2O5, Mn2O3, SrO, ZnO, Cr2O3, and Cl, with the laboratories roughly split between the two different sample preparations. Chemical data using traditional chemical analyses (the Reference Methods per ASTM C150) from the Cement and Concrete Reference Laboratory (CCRL) proficiency test program were included for comparison to the XRF results. Precision measures for within- and between-laboratory performance are presented as 1σ and 95 % limits (ASTM d2s). Accuracy criteria are based upon a two-sided 95 % prediction interval for the mean of two test results, defining the range of values one might expect for each analyte relative to a certified value of a reference material. Comparing to current C114 limits, based upon classical wet chemical analysis, within-lab precision for CaO is larger while SiO2 precision is similar to existing limits. Al2O3 and Fe2O3 precisions are substantially better, while for the remaining analytes, the precision is generally similar to C114 limits. A comparison of the ASTM accuracy criteria shows that CaO accuracy is poorer the current limit, SO3 is larger, SiO2 and Na2O are similar, while the remaining accuracy limits for XRF are generally better than the C114 criteria. The powder method shows a positive relative bias for CaO for the cements containing limestone at the < 5 % level, suggesting a need for more limestone-containing reference materials for powder method calibration for these cements.
Citation
Advances in Civil Engineering Materials

Keywords

accuracy, cement, chemical analysis, precision

Citation

Stutzman, P. (2014), PERFORMANCE CRITERIA FOR CHEMICAL ANALYSIS OF HYDRAULIC CEMENTS BY X-RAY FLOURESCENCE ANALYSIS, Advances in Civil Engineering Materials (Accessed November 10, 2024)

Issues

If you have any questions about this publication or are having problems accessing it, please contact reflib@nist.gov.

Created August 31, 2014, Updated September 4, 2020